WTC 600 LP / MP
11
Malfunctions
Version 06/05
5
Malfunctions
Malfunctions of the RO system are signaled with LEDs at the control panel (10) and indicated at the 
display.
Malfunctions on the admission-pressure unit are indicated with the red LED (26) on the control unit of 
the admission-pressure unit.
i
In case of a malfunction, the system is generally switched off and the drinking water production 
is interrupted.
If the malfunction can not be corrected, stop the drinking water production and notify the 
Kärcher Service.
Designation/Indication Possible Cause
Corrective Action
LED
fault
Metering container empty 
Sensor signal missing
Fill metering container and ac-
knowledge malfunction after-
wards
Kärcher Service
regeneration
Flushing of the pre-filter is active Not required, as the system 
switches on again automatically
tank full
Drinking water tank full
Switch defective
Not required, as the system 
switches on again automatically
Check switch;
if required, Kärcher Service
Display
CV exceeded
Conductance value of the 
drinking water too high
Kärcher Service
Hard water
Metering container empty
Fill metering container and 
acknowledge malfunction after-
wards
Pressure malfunction
Pressure of untreated water 
too low
Check untreated water supply
• Installation on building side
• Admission-pressure pump
• Hoses for untreated water
Indication
Possible Cause
Corrective Action
Red LED lights
Untreated water supply 
disconnected
Check and reestablish the untreated 
water supply.
After correcting the malfunction, 
press the “Reset” pushbutton (23).