Sterling SGM-250A Manual De Usuario

Descargar
Página de 18
                        Water Management Systems and Products 
Page 17 
preferably a garden hose if possible. Return it to the filter housing 
ensuring that the U-shaped gasket fits securely to the bottom of the 
strainer. Make sure that the strainer head gasket is secure. 
Reposition the strainer cover on top of the filter housing. 
 
On those models with a band clamp, replace the band clamp 
around the strainer cover and housing latching the T-bolt. Then 
push the latch handle towards the filter housing. The T-bolt latch 
does not need adjustment when installed. It is set at the factory for 
proper clamp compression.  
 
Bolted cover models require a torque sequence as follows: 12:00 to 
6:00, 3:00 to 9:00, 11:00 to 5:00, and 2:00 to 7:00. Bolt torque 
requirements are: 3/8” bolts (15 to 25 ft.lbs.), ½” bolts (45 to 55 
ft.lbs.), and 5/8” bolts (80 to 100 ft.lbs.). 
 
 
Service Notes