Delegate setup 
The  “Delegate  setup”  menu  comprises  the 
following entries: 
 
Max Speakers 
 
Max. Requests 
 
Operation Mode 
 
Voice Detection 
 
Auto Off Setup 
 
Max Speakers 
This menu point has two settings: 
 
Max. Total Speakers 
 
Max. Delegate Speakers 
Values: {1, 2, 3, 4, 5, 6, 7, 8} 
The  number  of  ‘Total  Speakers’  defines  the 
maximum  number  of  conference  units,  which  can 
speak at the same time. This includes both delegate 
and chairman units. 
The  number  of  ‘Delegate  Speakers’  defines  the 
maximum  number  of  Delegate  conference  units, 
which  are  allowed  to  speak  at  the  same  time  is 
defined as “Max Speakers”. 
Please observe that a Chairman Unit can always be 
switched  ON  as  long  as  the  number  set  in  ‘Max. 
Total Speakers’ are not exceeded.  
 
Max Requests 
“Max  Requests”  defines  how  many  delegate  units 
that  can  be  inserted  into  the  list  of  delegates 
requesting to speak at the same time. 
Values : {0, 1, …, 255} 
 
Operation Mode 
This menu point has two settings: 
 
Operation mode 
 
Interrupt 
 
Operation mode 
The “Operation Mode” determines the behaviour of 
the microphone system.  
Values: {Auto, Manual, FIFO, VOX}: 
 
Auto  (or  Automatic)  mode  allows  for  the 
microphone  units  to  be  switched  on 
immediately upon pressing the microphone 
ON/OFF button.  
This  is  indicated  by  a  red  light  in  the 
‘Speak’  lamp  in  the  microphone  unit. 
Pressing  the  microphone  ON/OFF  button 
again will turn the microphone off  
A Chairman Unit is always in Auto or VOX 
mode. 
 
Manual mode features a request list, where 
‘Delegates’  are  inserted  in  a  queue  upon 
pressing  the  microphone  ON/OFF  button. 
This is confirmed by a steady green light in 
the ‘Request’ lamp in the delegate unit. It is 
possible  to  cancel  the  request  by  pressing 
the button again. 
The  microphone  can  only  be  switched  on 
from  a  PC  running  SW  6000  software  or 
from  a  control  system  like  AMX  or 
Crestron. This will be indicated by red light 
in the ‘Speak’ lamp in the microphone unit. 
At this point the delegate can switch off the 
microphone  by  pressing  the  ON/OFF 
microphone button. 
Although  it  is  possible  to  switch  to  this 
mode in a stand-alone-system, this mode is 
only used with an attached PC running SW 
6000  software  or  using  with  a  control 
system. 
 
FIFO  is  an  automated  mode.  The 
microphone unit functions in the same way 
as in automatic mode as long as the number 
of  turned  on  delegate  units  is  less  or  equal 
to the selected maximum speakers.  
When the max. number is reached, the next 
delegate  pressing  the  ON/OFF  button  will 
be put in the top of the request queue. This 
is  indicated  by  the  green  ‘Request’  lamp 
flashing slowly.