Classe Audio SSP-30 MKII Manual De Usuario

Descargar
Página de 32
 
5.5  
TRIGGER  SETUP: 
 
There are three Voltage Triggers on the SSP-30 MKII. They are used to turn associated equipment on and off.  
 
These displays show that you have accessed the Trigger setup sub-menu and 
highlighted Trig1 sense.  You can scan through the available choices by pressing 
repeatedly the \/ and /\ buttons on the remote. When the selection you wish to adjust 
is highlighted press the < or > key to scroll through the choices. To memorize and 
Exit highlight Exit and press the ENTER key. 
Trigger setup 
 Trigger1 sense Power On 
 - 
polarity 
Posit. 
- delay 
     No 
- duration 
Infin. 
 Trigger 2 sense: Power On 
- polarity 
Posit. 
- delay 
     No 
- duration 
Infin. 
Exit 
 
Trigger setup 
Trig1 sense:                   Power On 
 
 
 
 
 
TV 
Display 
     Panel 
Display 
 
Trigger 1 controls the TRIGGER 1 voltage output and Trigger 2 controls the TRIGGER 2 and TRIGGER 3 outputs. 
Trigger 2 and Trigger 3 always turn On or Off at the same time. Use the \/ and /\ keys to select and use the < and > 
keys to cycle through the available choices. The following applies to both Trigger 1 and Trigger 2. 
 
5.5.1  Trigger sense selects what event will activate the Trigger output. Set “sense” to Power On to activate the 
trigger when switching out of STANDBY (and de-activate it when returning to STANDBY). Alternatively the 
trigger output may be activated when a particular Source is selected. 
 
5.5.2  Trigger polarity sets the polarity of the trigger output. “Posit.” provides a +12V DC output when the trigger is 
active and no voltage when inactive. “Negat.” sends no voltage output when the trigger is active and +12V 
when inactive. 
 
5.5.3  Trigger delay sets a delay between the “sense” signal and the trigger output voltage changing. The delay may 
be set to various times from 1 second to 3 minutes or to “No” which gives no delay. 
 
5.5.4  Trigger duration sets the period (duration) that the trigger output is active. The trigger duration may be set to 
various times from 10ms (milliseconds) to 3 minutes, or to “Infin.” which keeps the trigger active while the 
"sense" condition prevails. 
            
             Exit returns to the main menu 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
24