6. TROUBLESHOOTING 
 
No Audio 
 
•  Low or no remote turn-on voltage: check remote connections at the amplifier and 
source unit. 
•  Blown amplifier fuse: replace with a new fast-blow fuse (same rating). 
•  Power wires not connected: check battery and ground wiring at the amplifier and 
check the battery connections. 
•  Speaker leads shorted: check speaker continuity to ground; it should not show a 
common ground. 
•  Speakers not connected or are blown: check speaker connections at the 
amplifier; measure coil impedance. 
 
Audio cycles on and off 
 
•  Thermal protection circuits are shutting the amplifier off. 
•  Check the location for adequate ventilation. Consult an authorized Clarion audio 
dealer. 
Distorted audio 
•  Gain is not properly set or the speaker cones are damaged. 
•  Review the instructions for setting the gain. Inspect each speaker cone for signs 
of damage, such as a frozen cone, burning smell, etc. 
 
Amplifier fuse keeps blowing 
•  The wiring is connected incorrectly or there is a short circuit. 
•  Review the installation precautions and diagram in this manual and check all 
wiring connections. 
 
Whining or ticking noise when engine on 
•  The amplifier is picking up alternator or radiated noise. 
•  Turn down input gain. 
•  Move the audio cables away from the power wires. 
•  Check the power and ground connections on the amplifier and install an in-line 
noise filter on the source unit’s power wire. 
•  Check the alternator and/or voltage regulator. Test for a weak battery or add 
water to the battery.