Diagrams ___________________________________________________________  
 
 
 
 
 
Insert the ¼” bias meter plug into the bias jack on the back of the amplifier chassis. Connect the bias cable 
red alligator clip to the positive (+) connection on your meter. Connect the bias cable black alligator clip 
to the negative (-) connection on your meter. Check the 845 tube bias current reading and adjust for a 
100 mA reading on the Volt Ohm Meter (VOM) or DC current meter if the reading is different than 100 
mA DC current. Check and readjust to 100 mA again after the CAD 211 amplifier is warmed up for 10 
minutes. Remove the ¼” plug from the bias jack and enjoy the music!  
 
Note: Bias is factory preset to 100 mA. Bias should be reset when installing a new 
replacement 845 tube. 
 
The LARGE pair of 300B tube pins should be installed toward the front of the CAD 211 AE amplifier tube 
socket. Look carefully at the tube pins to be sure that you insert them correctly. It is possible to force the 
tube pins into the socket the wrong way if you are not careful! If you install the tube wrong you will 
probably damage the amplifier and the tube. This damage will not be covered by the manufacturers 
warranty for a new amplifier. If you have any doubts about this, have the 300B tube installed by your 
dealer. 
 
Set the 845 tube 
bias to 100 mA DC 
Current 
 
 
¼” bias plug