Trigger setup 
Trig1 sense:                   Power On 
 
  
Trigger setup 
 
   Trigger 1 sense Power On 
     - polarity              Posit. 
     - delay                     No 
     - duration             Infin. 
   Trigger 2 sense Power On 
     - polarity             Posit. 
     - delay                     No 
     - duration             Infin. 
    Exit 
 
5.5 
TRIGGER SETUP: 
 
There are three Voltage Triggers on the SSP-60. They are used to turn associated equipment on and off.  
 
These displays show that you have accessed the Trigger setup sub-menu and 
highlighted Trig1 sense.  You can scan through the available choices by pressing the \/ 
and /\ buttons on the remote. When the selection you wish to adjust is highlighted 
press the < or > key to scroll through the choices. To leave the menu and save the 
settings scroll down to Exit and press the ENTER key. 
 
 
 
 
 
 
     TV Display 
 
 
 
 
 
  Panel Display 
 
Trigger 1 controls the TRIGGER 1 voltage output and Trigger 2 controls the TRIGGER 2  and TRIGGER 3 outputs. 
TRIGGER 2 and TRIGGER 3 always turn On or Off at the same time. Use the \/ and /\ keys to select and use the < and 
> keys to cycle through the available choices. The following applies to both Trigger 1 and Trigger 2. 
 
5.5.1  Trigger sense selects what event will activate the Trigger output. Set “sense” to Power On to activate the trigger 
when switching out of STANDBY (and de-activate it when returning to STANDBY). Alternatively the trigger output 
may be activated when a particular Source is selected. 
 
5.5.2  Trigger polarity sets the state of the trigger output. “Posit.” provides a +12V DC output when the trigger is active 
and no voltage when inactive. “Negat.” sends no voltage output when the trigger is active and +12V when 
inactive. 
 
5.5.3  Trigger delay sets a delay between the “sense” signal and the trigger output voltage changing. The delay may be 
set to various times from 1 second to 3 minutes or to “No” which gives no delay. 
 
5.5.4  Trigger duration sets the period (duration) that the trigger output is active. The trigger duration may be set to 
various times from 10ms (milliseconds) to 3 minutes, or to “Infin.” which keeps the trigger active while the "sense" 
condition prevails. 
 
Exit returns to the main menu