Peavey VR112 Manual De Usuario

Descargar
Página de 6
Chart for Changes with Number of Cabinets 
No. 
of 
Cabs: 
1   2   3   4   6   8 
 
218 Sub  
Level: -6.0 
dB -2.5 
dB -0.5 
dB +1.5 dB 
+4 dB  
+5.5 dB 
 
12” Wfr 
0.0 dB  
0.0 dB  
0.0 dB  
0.0  dB  
0.0  dB  
0.0  dB 
Level: 
 
Twtr 
 0.0 
dB 
 +2.0 
dB 
+4.0 
dB +5.5dB  +6.5 
dB +7.0 
dB 
Level: 
(Drive levels are for  factory 16 ohm wiring, for 4 ohm wiring, subtract 6 dB) 
 
Front Block EQ 
at 
kHz -2.0 
dB  -   -   -   -   - 
 
at 1.8 kHz 
 
-3.0 dB 
-3.5 dB -3.5 
dB -4.0 
dB -4.5 
dB 
(at a bw set to 0.577) 
 
     bw=.707 
bw=.707 
 
† SPECIAL NOTE:  Versarray
 218 Sub is supplied in 4 ohm mode (woofers 
paralleled). 
If the Versarray
 218 Sub woofers are driven separately, using an amp with the 
same gain as all the other amps, then drive level to the separate woofers is the 
same. 
 
To convert the above drive levels for a single Versarray
 218 Sub to drive levels 
suitable for a single Versarray
 118 Sub, add 6 dB. 
 
When doubling the number of Subs, subtract 6 dB for each time they are doubled. 
 
 
 SPECIAL NOTE:  To match this PEQ setting with a 1/3 octave band EQ, use the 
following: 
 
To equate to a PEQ setting of –3 dB @ 1.8k, bw= 0.6 use, 1/3 octave band 2 kHz set 
to –1.5 dB AND 1/3 octave band 1.6 kHz also set to –1.5 dB 
 
To equate to a PEQ setting of –3.5 dB @ 1.8k, bw= 0.6, use 1/3 octave band 2 kHz 
set to –2 dB AND 1/3 octave band 1.6 kHz set to –1.5 dB 
 
To equate to a PEQ setting of –4 dB @ 1.8k, bw= 0.7 (or use 1/3 octave band 2 kHz 
set to –2.0 dB AND 1/3 octave band 1.6 kHz set to –2.0 dB 
 
To equate to a PEQ setting of –4.5 dB @ 1.8k, bw= 0.7 (or use 1/3 octave band 2 
kHz set to –2.5 dB AND 1/3 octave band 1.6 kHz set to –2.0 dB