Crown Audio CTS4200A Manual De Usuario

Descargar
Página de 60
page 19
CTs Power Amplifi ers
Operation Manual
5 Advanced Features
and Options
5.2.4 Input Sensitivity Switches
See Figures 5.1 and 5.2. To access the Input Sensitivity Switches, turn off the 
amplifi er and remove the PIP2-BBY Input Panel. The switches are in the top surface 
of the cavity behind the Input Panel. One 3-position switch per channel selects 
among these settings: CTs 600/1200: 1.4V (8/4 ohms), 26 dB gain, and 1.4V (70V 
operation). CTs 2000/3000: 1.4V (8/4 ohms), 26 dB gain, and 1.4V (70V) / 2V 
(100V). The Specifi cations chapter lists the input sensitivity for the 26 dB gain 
set ting.
5.3  Options
T-170V: See Figure 5.3. This is an autoformer that 
allows 100V output from the CTs 600/1200, and allows 
other amplifi ers without direct constant voltage output 
to be easily integrated into distributed systems.
TP-170V: See Figure 5.4. This is a rack-mountable 
panel with four autoformers as described above. 
PIP Modules
Versatile PIP (Programmable Input Processor) 
mod ules provide fl exible expansion features that can 
be added to customize the amplifi er. PIP modules plug 
into the connector inside the back panel of the 
ampli fi er. PIP modules are available with features 
ranging from error-driven compressor/limiters to 
crossovers to remote control and monitoring via 
IQwic™ or System Architect software. Your amplifi er is 
a PIP2 amplifi er, which means it can take advantage of 
the many advanced features found in PIP2 modules. 
The CTs Series 2-channel models do not accept earlier 
PIP
 
modules.
Visit the Crown website at www.crownaudio.com, or 
contact Crown Customer Service, for descriptions of 
available PIP and PIP2 modules. 
Figure 5.2  Input Sensitivity Switches for CTs 2000/3000 
Figure 5.1  Input Sensitivity Switches for CTs 600/1200
Figure 5.3  T-170V
Figure 5.4 TP-170V (back view)