Yamaha RX-V2600 Manual De Usuario

Descargar
Página de 135
119
TROUBLESHOOTING
ADDITIONA
L
 
INF
O
RMA
T
IO
N
English
■ AUTO SETUP
Before AUTO SETUP
During AUTO SETUP
Error message
Cause
Remedy
See 
page
Connect MIC!
Optimizer microphone is not connected.
Connect the supplied optimizer microphone to the 
OPTIMIZER MIC jack on the front panel.
Unplug Phones!
Headphones are connected.
Unplug the headphones.
No Setup Menu!
No setup menu items have been selected.
Select at least one setup menu item.
Memory Guard!
This setting is protected.
Remove the protection setting for AUTO SETUP.
Error message
Cause
Remedy
See 
page
E01:No Front SP
Front L/R channel signal(s) is (are) not 
detected.
Select the front speakers by pressing SPEAKER A or 
B on the front panel (or by setting AMP/SOURCE/
TV to AMP and then pressing SPEAKER A or B on 
the remote control).
Check the front L/R speaker connections.
E02:No Surr. SP
A surround channel signal is not detected.
Check the surround speaker connections.
E03:No PRNS SP
A presence channel signal is not detected.
Check the presence speaker connections.
E04:SBR–>SBL
Only right surround back channel signal is 
detected.
Connect the surround back speaker to the LEFT 
SURROUND BACK SPEAKERS terminal if you 
only have one surround back speaker.
E05:Noisy
Background noise is too loud.
Try running AUTO SETUP in a quiet environment.
Turn off noisy electric equipment like air conditioners 
or move them away from the optimizer microphone.
E06:Check Surr.
Surround back speaker(s) is (are) 
connected, though surround L/R speakers 
are not.
Connect surround speakers when you use (a) 
surround back speaker(s).
E07:No MIC
The optimizer microphone was unplugged 
during the AUTO SETUP procedure.
Connect the supplied optimizer microphone to 
OPTIMIZER MIC jack on the front panel.
E08:No Signal
The optimizer microphone does not detect 
test tones.
Check the microphone setting.
Check the speaker connections and placement.
E09:User Cancel
The AUTO SETUP procedure was 
cancelled due to user activity.
Run AUTO SETUP again. 
E10:Internal Err
An internal error occurred.
Run AUTO SETUP again.