20.4.3
Scan Mode (MULTI = 1, SCN = 1)
Scan mode is useful for monitoring analog inputs in a group of one or more channels.  When the
ADST bit in the A/D control/status register (ADCSR) is set to 1 by software or external trigger
input, A/D conversion starts on the first channel in the group (AN0 when CH2 = 0, AN4 when
CH2 = 1)).  When two or more channels are selected, after conversion of the first channel ends,
conversion of the second channel (AN1 or AN5) starts immediately.  A/D conversion continues
cyclically on the selected channels until the ADST bit is cleared to 0.  The conversion results are
transferred for storage into the A/D data registers corresponding to the channels.
When the mode or analog input channel must be changed during analog conversion, to prevent
incorrect operation, first clear the ADST bit to 0 to halt A/D conversion.  After making the
necessary changes, set the ADST bit to 1.  A/D conversion will start again from the first channel
in the group.  The ADST bit can be set at the same time as the mode or channel selection is
changed.
Typical operations when three channels (AN0 to AN2) in group 0 are selected in scan mode are
described next.  Figure 20.5 shows a timing diagram for this example.
1. Scan mode is selected (MULTI = 1, SCN = 1), channel group 0 is selected (CH2 = 0), analog
input channels AN0 to AN2 are selected (CH1 = 1, CH0 = 0), and A/D conversion is started
(ADST = 1).
2. When A/D conversion of the first channel (AN0) is completed, the result is transferred into
ADDRA.  Next, conversion of the second channel (AN1) starts automatically.
3. Conversion proceeds in the same way through the third channel (AN2).
4. When conversion of all the selected channels (AN0 to AN2) is completed, the ADF flag is set
to 1 and conversion of the first channel (AN0) starts again.  If the ADIE bit is set to 1, an ADI
interrupt is requested at this time.
5. Steps 2 to 4 are repeated as long as the ADST bit remains set to 1.  When the ADST bit is
cleared to 0, A/D conversion stops.  After that, if the ADST bit is set to 1, A/D conversion
starts again from the first channel (AN0).