Rev. 5.00, 09/03, page 670 of 760
23.3.2
Control Signal Timing
Table 23.6
Control Signal Timing
Vcc = 3.3 ± 0.3 V, Vcc = 1.55 to 2.15 V, AVcc = 3.3 ± 0.3 V, Ta = –20 to 75°C
Item
Symbol
Min
Max
Unit
Figure
RESETP
 pulse width
t
RESPW
20 
*
2
tcyc
23.11,
RESETP
 setup time
*
1
t
RESPS
20
ns
23.12
RESETP
 hold time
t
RESPH
4
ns
RESETM
 pulse width
t
RESMW
20 
*
3
tcyc
RESETM
 setup time
t
RESMS
6
ns
RESETM
 hold time
t
RESMH
34
ns
BREQ
 setup time
t
BREQS
6
ns
23.14
BREQ
 hold time
t
BREQH
4
ns
NMI setup time 
*
1
t
NMIS
10
ns
23.12
NMI hold time
t
NMIH
4
ns
IRQ5–IRQ0 setup time 
*
1
t
IRQS
10
ns
IRQ5–IRQ0 hold time
t
IRQH
4
ns
IRQOUT
 delay time
t
IRQOD
10
ns
23.13
BACK
 delay time
t
BACKD
10
ns
23.14,
STATUS1, STATUS0 delay time
t
STD
10
ns
23.15
Bus tri-state delay time 1
t
BOFF1
0
15
ns
Bus tri-state delay time 2
t
BOFF2
0
15
ns
Bus buffer-on time 1
t
BON1
0
15
ns
Bus buffer-on time 2
t
BON2
0
15
ns
Notes: 1.
RESETP
, NMI, and IRQ5 to IRQ0 are asynchronous.  Changes are detected at the
clock fall when the setup shown is used.  When the setup cannot be used, detection
can be delayed until the next clock falls.
2. In the standby mode, t
RESPW
 = t
OSC1
 (100 µs) when XTAL oscillation is continued and
t
RESPW
 = t
OSC2
 (10 ms) when XTAL oscillation is off. In the sleep mode, t
RESPW
 = t
PLL1
(100 µs).
When the clock multiplication ratio is changed, t
RESPW
 = t
PLL1
 (100 µs).
3. In the standby mode, t
RESMW
 = t
OSC2
 (10 ms).  In the sleep mode, 
RESETM
 must be kept
low until STATUS (0-1) changes to reset (HH).  When the clock multiplication ratio is
changed, 
RESETM
 must be kept low until STATUS (0-1) changes to reset (HH).