Renesas SH7709S Manual De Usuario
Rev. 5.00, 09/03, page 706 of 760
23.3.8
Peripheral Module Signal Timing
Table 23.8
Peripheral Module Signal Timing
VccQ = 3.3 ± 0.3 V, Vcc = 1.55 to 2.15 V, AVcc = 3.3 ± 0.3 V, Ta = –20 to 75°C
Module
Item
Symbol
Min
Max
Unit
Figure
Timer input setup time
t
TCLKS
15
—
ns
23.47
TMU,
RTC
RTC
Timer clock input setup time
t
TCKS
15
—
23.48
Edge specification
t
TCKWH
1.5
—
Pcyc
Timer clock
pulse width
pulse width
Both edge specification
t
TCKWL
2.5
—
Oscillation settling time
t
ROSC
3
—
s
23.49
SCI
Asynchronization
t
SCYC
4
—
Pcyc
*
23.50
Input clock
cycle
cycle
Clock synchronization
6
—
23.51
Input clock rise time
t
SCKR
—
1.5
23.50
Input clock fall time
t
SCKF
—
1.5
Input clock pulse width
t
SCKW
0.4
0.6
tscyc
Transmission data delay time
t
TXD
—
100
ns
23.51
Receive data setup time (clock
synchronization)
synchronization)
t
RXS
100
—
Receive data hold time (clock
synchronization)
synchronization)
t
RXH
100
—
RTS
delay time
t
RTSD
—
100
CTS
setup time (clock synchronization)
t
CTSS
100
—
CTS
hold time (clock synchronization)
t
CTSH
100
—
Port
Output data delay time
t
PORTD
—
17
ns
23.52
Input data setup time
t
PORTS1
15
—
Input data hold time
t
PORTH1
8
—
Input data setup time
t
PORTS2
tcyc +
15
15
—
Input data hold time
t
PORTH2
8
—
Input data setup time
t
PORTS3
3
×
tcyc
+ 15
—
Input data hold time
t
PORTH3
8
—
DMAC
DREQ
setup time
t
DRQS
6
—
ns
23.53
DREQ
hold time
t
DREQH
4
—
DRAK delay time
t
DRAKD
—
10
23.54
Note:
*
Pcyc is the P clock cycle.