Crestron electronic C2N-VEQ4 Manual De Usuario

Descargar
Página de 40
Cresnet 4-Channel Digital Volume Control 
Crestron C2N-VEQ4
 
10  
  Cresnet 4-Channel Digital Volume Control: C2N-VEQ4 
Operations Guide - DOC. 6135A 
“Set Net ID by TSID” Window 
 
4. 
Click on the Search for Touch Settable Devices button. The system 
searches the network and lists all TSID-enabled devices found. The list 
is similar to the report produced by pressing F4 (Report Network 
Devices); the first eight digits of each line constitute the TSID number 
(hexadecimal form of the serial number).  
5. 
As you enter either the serial number or TSID number of the device that 
requires a change, the corresponding TSID or serial number 
automatically appears in its appropriate field, and the list scrolls to and 
highlights the device listing. The listing should show the device’s 
current Cresnet ID. 
6. 
Enter the Cresnet ID that the device should be set to and click OK. The 
number you enter should appear on the list. 
CAUTION: This function does not prevent you from setting duplicate IDs. Be sure 
to check current assignments before entering the desired Cresnet ID number. 
Serial Number to TSID Conversion 
This utility is useful in a case where there are multiple devices of the same type on a 
network, you need to locate a particular one, you know the TSID but not the serial 
number, and your site installation list is based on device serial numbers. In this (or the 
reverse) situation, do the following: 
1. 
Open the Crestron Viewport.  
2. 
From the Viewport menu, select Functions | Serial Number ÅÆ 
TSID Conversion Tool
. The “Serial Number ÅÆTSID Conversion 
Tool” window is displayed.