Cresnet 4-Channel Digital Volume Control 
Crestron C2N-VEQ4
 
28  
  Cresnet 4-Channel Digital Volume Control: C2N-VEQ4 
Operations Guide - DOC. 6135A 
“Port Settings” Window 
 
NOTE: The parameters shown in the illustration on the previous page are the port 
settings for a 2-Series control system. Consult the Operations Guide for the control 
system being used for exact parameter selection. 
5.  To verify communication, select Diagnostics | Establish 
Communications (Find Rack). This should display a window that 
gives the COM port and baud rate. If communication cannot be 
established, refer to the “Troubleshooting Communications” section in 
the respective Operations Guide for the control system.  
Uploading a SIMPL Windows Program 
A control system source file has 
the extension .smw. A compiled 
SIMPL Windows file has the 
extension .spz for a 2-Series 
control system, .bin for CNX 
generation, and .csz for CNX 
generation with SIMPL+. 
The SIMPL Windows file can be uploaded to the control system using SIMPL 
Windows or via the Crestron Viewport.  
Upload via SIMPL Windows 
1.  Start SIMPL Windows. 
2. Select 
File | Open to view the “Open” window, navigate to the SIMPL 
Window file (.smw), and click Open
3. Select 
Project | Transfer Program.  
Upload via Crestron Viewport 
1.  Verify that the procedure for “Communication Settings” that begins on 
2.  As shown after this step, select File Transfer | Send Program 
(alternatively, press Alt+P) from the Viewport menu.