Crestron electronic C2N-VEQ4 Manual De Usuario

Descargar
Página de 40
Crestron C2N-VEQ4 
Cresnet 4-Channel Digital Volume Control
 
Operations Guide - DOC. 6135A 
Cresnet 4-Channel Digital Volume Control: C2N-VEQ4  
  31 
“Open” Window 
 
 
4.  Browse to the desired .upg file and click Open to begin the transfer.  
Problem Solving 
Troubleshooting 
The following table provides corrective action for possible trouble situations. If 
further assistance is required, please contact a Crestron customer service 
representative.  
C2N-VEQ4 Troubleshooting 
TROUBLE 
PROBABLE 
CAUSE(S) 
CORRECTIVE ACTION 
Wrong power 
supply. 
Use a Crestron power supply. 
Green PWR 
LED does not 
illuminate. 
C2N-VEQ4 is 
not receiving 
power. 
Verify that cables plugged into NET port are 
secure. 
Improper Net 
ID. 
Verify that the C2N-VEQ4 Net ID matches Net 
ID in the software program. 
Yellow NET 
LED does not 
illuminate. 
Loose network 
connection. 
Verify that cable plugged into NET port is 
secure. 
Red ACTIVITY 
1, 2, 3, 4 LEDs 
do not 
illuminate. 
Improper 
programming. 
Confirm signal names and programming logic 
so that LEDs respond when functions are 
activated. Refer to “Programming with SIMPL 
Windows” in this Operations guide for an 
example. 
Hum on audio. 
Grounding 
problem. 
Connect or remove chassis ground. 
No audio on 
one or more 
channels. 
Mute enabled in 
error. 
Disable mute.