GE DCVH680EJBB Manual De Usuario

Descargar
Página de 12
Questions or Installation?  Call:  1-800-GECARES (US)
or Visit our Web site at:  www.GEAppliances.com (US)
  
Installation
Instructions
Electric Dryer
09
Step 1 Prepare the Area and Exhaust for Installation of New
Dryer (see section 1).
Step 2 Check and Ensure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Specifications (see section 3).
Step 3 Remove the Foam Shipping Pads (see section 1).
Step 4 Move the Dryer to the Desired Location.
Step 5 Connect the Power Supply (see section 2).
Step 6 Connect the External Exhaust (see section 4).
Step 7 Level Your Dryer (see section 5).
Step 8 Check the Operation of the Power Supply and
Venting.
Step 9 Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be
Noticed By the Owner.
For Alcove or Closet Installation, see section 6.
For Bathroom or Bedroom Installation, see section 7.
For Mobile or Manufactured Home see, section 8.
For side or bottom exhaust, see section 9.
500A436P009_Rev0
Pub # 31-16228
PEDESTALS FOR DRYERS
 (comes with individual installation instructions)
Three models available:
- SBSD227F
- SBSD137H
- SBSD107H
NOTE:  Installation and service of this dryer 
requires basic mechanical and electrical skills.  
It is your responsibility to contact a qualified 
installer to make the electrical connections.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT-
Save these instructions for local   
inspector’s use.
IMPORTANT-
Observe all governing codes and     
ordinances.  
• Note to Installer - Be sure to leave these instructions with  
the customer.
• Note to Customer - Keep these instructions with your Use  
and Care Book for future reference. 
 Before the old dryer is removed from service or discarded,  
remove the dryer door.
 Service information and the wiring diagram are located in   
the control console. 
 Do not allow children on or in the appliance.  Close super- 
vision of children is necessary when the appliance is used  
near children. 
 Install the dryer where the temperature is above 50°F for 
satisfactory operation of the dryer control system.
MATERIALS YOU WILL NEED
GLOVES
SAFETY
GLASSES
DRYER POWER CORD
KIT (NOT PROVIDED
WITH DRYER)
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST
HOOD
3/4" STRAIN
RELIEF
UL RECOGNIZED
4" DIA. METAL
ELBOW
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
 KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
DUCT TAPE
UL RATED 
120/240V,30A       
WITH 3 OR 4 PRONGS. 
IDENTIFY THE PLUG 
TYPE AS PER THE 
HOUSE RECEPTACLE 
BEFORE PURCHASING 
LINE CORD. 
TOOLS YOU
WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
PHILLIPS SCREWDRIVER
LEVEL
- RISK OF FIRE
 
    
WARNING
•  To reduce the risk of severe injury or death, follow all installation instructions.
•  Clothes dryer installation must be performed by a qualified installer.
•  Install the clothes dryer according to these instructions and in accordance 
with local codes.
•  This dryer must be exhausted to the outdoors.
•  Use only 4” rigid metal ducting for exhausting the clothes dryer to the 
outdoors.
•  Do not install or store this appliance in any location where it could be 
exposed to water and or weather.
•  Save these instructions.  (Installers: Be sure to leave these instructions with 
the customer).
•  DO NOT install a clothes dryer with flexible plastic ducting materials.
If flexible metal (semi-rigid or foil-type) duct is installed, it must be UL listed 
and installed in accordance with the instructions found in "Connecting The 
Dryer To House Vent" on page 5 of this manual.  Flexible venting materials 
are known to collapse, be easily crushed, and trap lint.  These conditions will 
obstruct dryer airflow and increase the risk of fire.