Note: Cabinets installed adjacent to wall ovens must have an 
adhesion spec of at least a 194°F temperature rating. 
Most 30" Wall Cabinets can be used with this unit. 
Note: 2" minimum between cutouts when installed above 
warming drawer or single wall oven.
Installation Information: Before installing, consult installation 
instructions packed with product for current dimensional data.
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service, 
800.626.2000.
Listed by 
Underwriters 
Laboratories
SCB2001K 
GE Profile Advantium
®
 Wall Oven
 
Advantium_Install_dim.eps
Cutout width
28-1/2" 
30
Required
cutout location
36-3/4" 
minimum
from floor
Junction 
box
location
A=Allow 1" overlap of oven over top and bottom edges of cutout.
B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.
4-3/16
21"
Cutout height
A
B
19"
Cutout depth
29-25/32
21-7/8
15-27/32"
Excluding
Handle
Advantium Wall Oven Dimensions (in inches)and 
Cabinet Installation (in inches)
Note: Cabinets installed adjacent 
to wall ovens must have an adhesion 
spec of at least 194° F temperature rating.
Construct Solid
Bottom Min. 
3/8" Plywood
Supported by
2 x 4 or 1 x 2
Runners, all 
Four Sides.
(Must Support
150 lbs.)
Conduit
(48-1/2" 
long)
A
Allow 1" overlap of oven over top and bottom edges of cutout
B
Allow 11/16"-3/4" for overlap of oven over side edges of cutout
240440
Specification Revised 2/07