Cerwin-Vega CV-5000 Manual De Usuario

Descargar
Página de 19
12 
 
Mode Select 
 
 
 
 
Stereo Mode 
In stereo mode, both channels operate independently, with their input gain controls. Signal at 
channel 1’s input produces output at channel 1, while signal at channel 2’s input produces 
output at channel 2’s output. Recommended minimum nominal load impedance for stereo 
operation is 2 ohms per channel.  
 
 
Parallel Mode 
When set to Parallel mode, a signal applied to channel 1’s input will be amplified and appear 
at outputs for both channel 1 & 2. With set to parallel. The parallel mode is well-suited for 
applications in which driving two speakers with the same signal but with separate 
amplification. 
 
 
Bridged Mono Mode 
Bridged mono mode straps both amplifier channels together to make a very powerful, single-
channel monaural amplifier. One channel ”pushes” and the other channel “pulls” equally, 
doubling the power over that of either channel alone. Therefore the voltage is doubled, the 
peak power is quadrupled, and program power is roughly three times as high as that of the 
individual channel. 
 
Signal is applied to the channel 1 input only and channel 1 input gain control is used to adjust 
signal level. The input gain control belonging to channel 2 are not used. 
 
 
Note : Bridged mono mode is to be used only when the CV-5000 is connected to a 4 or 8 
ohms speaker load. Use of Bridged mode with speaker loads of 4 ohms or less can result in 
severe damage to the unit due to excessive heat and current limiting.  
Use extreme caution when operating the amplifier in Bridged Mono Mode. Never ground 
either side of the speaker cable when the amplifier is in Bridged Mono Mode ; the speaker 
load must “ float “ away from the amplifier chassis.