8. PARAMETER UNIT (MR-PRU03)
8.5.6 Point table mode
The flowchart below shows the procedure for setting point table data.
DATA
PARAM
e.g. To set setting
value "4567.89",
press:
value "4567.89",
press:
SHIFT
Servo motor speed display
Acceleration time
constant display
constant display
Deceleration time
constant display
constant display
Dwell display
Auxiliary function display
Select a point table No.
Position data display
e.g. To set point
table No."255"
press:
table No."255"
press:
Table read screen
4 5 6 7
8 9
1STEP
2 5 5
Select an item with
the keys
or numeric keys.
the keys
or numeric keys.
Enter
e.g. To set setting
value "0", press:
value "0", press:
0
Enter
(Note)
Press the "Fn" key
to display the range.
to display the range.
Point table data is
displayed.
POS
SPD
ACC
DEC
DWELL
AUX
displayed.
POS
SPD
ACC
DEC
DWELL
AUX
: Point data
: Servo motor
speed
: Acceleration
time constant
: Deceleration
time constant
: Dwell
: Auxiliary
function
: Servo motor
speed
: Acceleration
time constant
: Deceleration
time constant
: Dwell
: Auxiliary
function
"
"
Note. This applies to all types of data.