Mitsubishi Electronics MR-J3 Manual De Usuario
14 - 19
14. OPTIONS AND AUXILIARY EQUIPMENT
14.2 Regenerative options
CAUTION
The specified combinations of regenerative options and servo amplifiers may only
be used. Otherwise, a fire may occur.
be used. Otherwise, a fire may occur.
(1) Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
Regenerative power[W]
Servo amplifier
Built-in
regenerative
resistor
MR-RB032
[40 ]
MR-RB12
[40 ]
MR-RB30
[13 ]
MR-RB31
[6.7 ]
MR-RB32
[40 ]
(Note 1)
MR-RB50
[13 ]
(Note 1)
MR-MB51
[6.7 ]
MR-J3-10T
(1)
30
MR-J3-20T
(1)
10
30
100
MR-J3-40T
(1)
10
30
100
MR-J3-60T
10
30
100
MR-J3-70T
20 30 100 300
MR-J3-100T
20 30 100 300
MR-J3-200T
100 300 500
MR-J3-350T
100 300 500
MR-J3-500T
130 300 500
MR-J3-700T
170 300 500
Regenerative
power[W]
Servo amplifier
Built-in
regenerative
resistor
MR-RB1H-4
[82 ]
(Note 1)
MR-RB3M-4
[120 ]
(Note 1)
MR-RB3G-4
[47 ]
(Note 1)
MR-RB5G-4
[47 ]
(Note 1)
MR-RB34-4
[26 ]
(Note 1)
MR-RB54-4
[26 ]
MR-J3-60T4 15 100 300
MR-J3-100T4 15 100 300
MR-J3-200T4 100
300 500
MR-J3-350T4 100
300 500
MR-J3-500T4
130
300
500
MR-J3-700T4
170
300
500
(Note 2) Regenerative power[W]
Servo amplifier
External regenerative
resistor (Accessory)
MR-RB5E
[6 ]
MR-RB9P
[4.5 ]
MR-RB9F
[3 ]
MR-RB6B-4
[20 ]
MR-RB60-4
[12.5 ]
MR-RB6K-4
[10 ]
MR-J3-11KT
500 (800)
500 (800)
MR-J3-15KT
850
(1300)
850
(1300)
MR-J3-22KT
850
(1300)
850
(1300)
MR-J3-11KT4
500
(800)
500
(800)
MR-J3-15KT4
850
(1300)
850
(1300)
MR-J3-22KT4
850
(1300)
850
(1300)
Note 1. Always install a cooling fan.
2. Values in parentheses assume the installation of a cooling fan.