Kathrein VOS 952-1G/953-1G Manual De Usuario

Descargar
Página de 11
 
1
1
HTE 10 - Hand-held unit
With the HTE 10 hand-held unit one is able to adjust 
correspondingly equipped devices on site. Using the 
'Up' and 'Down', 'Menu' and 'Enter' buttons, one is able 
to change and set the values on the 4-line display. The 
display is illuminated and easy to read. 
Accessories
Monitoring transponder HMS protocol,  
frequency-agile
TVM 1000 - Monitoring transponder DOCSIS/
EuroDOCSIS, frequency-agile
Type
TVM 850/H
Order no.
26210077
Input frequency range
MHz
75-90.5
Input level range
dBµV
50-95
Output frequency range
MHz
5-42
Max. output level
dBµV
105
Power consumption
W
1
Transmission protocol
HMS
Suitable for
VGO 939, VGF 939, VGO 939-1G, VGF 939-1G, VOS 952/953, VOS 952-1G, 
VOS 953-1G, ORA 9022, ORA 9022-1G, ORA 920/921, VGP 9033, 
VGP 9033-1G, VGP 9041, VGF 9030/9040
Type
TVM 1000
Order no.
26210086
Input frequency range
MHz
90-862
Input level range
dBµV
48-78
Output frequency range
MHz
5-65
Max. output level
dBµV
113-118
Power consumption
W
3.5
Transmission protocol
DOCSIS/EuroDOCSIS 2.0
Suitable for
VGO 939, VGO 939-1G, VGF 939, VGF 939-1G, VOS 952/953, VOS 952-1G,  
VOS 953-1G, ORA 9022, ORA 9022-1G, ORA 920/921, VGP 9033 as of version A03  
(Nov. 2008), VGP 9033-1G, VGP 9041 as of version A02 (Nov. 2008), VGF 9030/9040
• Monitoring transponder for compact amplifiers, house connec-
tion amplifiers and optical compact receivers (see table)
• Monitors various parameters such as voltage, current drain and 
internal temperature
• Controls the Ingress Control switch in correspondingly equip-
ped devices
• Transmission in the HMS protocol
• Frequency-agile in range 5-42 MHz
• Monitoring transponder for compact/house connection amplifiers and optical com-
pact receivers (see table)
• Monitors various parameters such as voltage, current drain and internal temperature
• Controls the Ingress Control switch in correspondingly equipped devices
• Transmission in DOCSIS or EuroDOCSIS protocol
• Frequency-agile in range 5-65 MHz and 90-862 MHz
The hand-held unit presents the following 
functions:
• All appropriately equipped devices or modules can be 
adjusted and operated
• All settings are displayed
• The last settings are saved (copy function)
• The hand-held unit is power-supplied by the respective 
module
• Distances: 
Data transfer between HTE 10 and the device or  
module over max. 14 m 
Standard connection cable: 2 m (included in delivery 
scope) 
Can be extended to 14 m (TDK 10)
-
-
-
• 4-line display, illuminated
• Language: English
• Splash-proof/shock-proof
• Ambient conditions:  
- Ambient temperature: -20 to +50 °C  
- Suitable for outdoor application  
- Protection category: IP 54
• Control signal: Serial, RS 232
• Connection: Sub D, 9-pin
• Accessories (not included in delivery scope):  
TDK 10 (Order no. 26210054): Connection cable 14 m 
TDK 12 (Order no. 26210076): PC connection cable for 
HTE 10 (for software updates)