DSR-6400 Series 
41 
 
Alarm Menu
Use this menu to choose which alarm condition will activate an alarm. Press the  button until 
the Alarm menu is located (shown below). 
The alarm can be activated for any of the following conditions: 
The unit’s tuner loses lock when the input is RF.
The unit cannot lock to the ASI input when the input is ASI.
The unit is unable to render video.
The unit is not authorized to access the selected service.
The unit loses power.
The unit’s GigE Port Link state is inactive when the Input field (described on page 32) is 
set to GigE In.
Trigger Field
Default: Auto
The Trigger field allows the user to select the trigger condition to activate an alarm on the IRD. 
When the alarm is activated, the Alarm LED illuminates and the alarm relay indicates an alarm 
condition. 
Press the 4 button until the cursor is at the Trigger label, and press ENTER to move into the field. 
Press the  buttons to display the five options:  
Disabled
Disables the IRD alarm feature.
Auto
Enables all triggers for an IRD alarm.
Auto+HDD
Alarm is triggered when the IRD detects a hard drive fault.
No Signal
Alarm is triggered when the IRD loses the incoming signal.
No Video
Alarm is triggered when the IRD loses analog video output.
No Auth (Authorization)
Alarm is triggered when the IRD is not authorized to access a 
selected service.
Press ENTER to select the desired option and exit the field.
Test Field
Default: Off
Note: The Test field returns to the default value (Off) when the field is exited.
The Test field provides an IRD alarm test when this field is set to On. Press the  buttons to 
display the two options: Off or On.
Press ENTER to select the option shown and exit the field.
E        Auto             Off
ALARM      Trigger         Test