JAI M7+ CL Manual De Usuario

Descargar
Página de 31
CV-M4
+
/M4
+
CL, CV-M7
+
/M7
+
CL
 
 
- 18 - 
 
 
6.6. Pulse Width Control Mode  
In this mode the exposure starts from the leading edge of the trigger pulse, H synchronous or H 
a-synchronous. It stops at the trailing edge of the trigger pulse, and the resulting video is read 
out. This mode will operate with full and partial scanning and with all binning modes (M4
+
 and 
M4
+
CL only). Partial scanning and binning in combinations is not allowed. The pulse width control 
mode can be used for long time integration. 
If smearless read out (SL=1) is used, the exposure starts with a delay 133H after the trigger. The 
trigger pulse width should be longer than 133 H (5.23 msec.) 
An EEN pulse will indicate the active accumulation time, and a FEN pulse indicates that the 
resulting video is read out. 
 
To use this mode:  
Set function:  
Trigger mode “Pulse Width Control”    
TR = 2 
 
 
“H synchronous trigger”   
 
HC=0, HC=1 
  “Smearless 
readout” 
  SL=0, 
SL=1 
 
 
 
Polarity and other functions 
Input: 
 
Ext. trigger to LVDS/Camera Link or pin 10 on 12-pin connector.   
 
 
Important notes on using this mode.
 
•  The duration of the trigger can be >2H to ∞. (>72.64µsec.). Thermal noise and dark 
current noise will increase by accumulation time, therefore the exposure time is not 
recommended to exceed 2 seconds. 
•  The minimum trigger interval should be >(exposure time + 1 frame). A new trigger must 
not be applied during the previous frame read out. (Before FEN is high). 
 
 
 
 
Fig. 22. Pulse Width