6.10. Smearless Mode 
This mode will reduce the unwanted smear signal from a highlighted scene when a short 
exposure time is used. The trigger mode is like edge pre-select, but a dummy readout is 
performed before the active accumulation is started. It will remove the smear above the 
highlighted parts in the image, but there is still smear left below highlighted areas. 
The trigger leading edge will start the dummy readout. It takes 54 H before the exposure starts. 
The exposure stops and the resulting video signal is read out after the selected shutter time. It 
can be the 16 step normal or 1023 step programmable. SM=0 or SM=1.  
This mode will operate with full and partial scanning and with all binning modes. Partial 
scanning together with binning will work, but it is not described, and no timing diagrams will be 
documented.  An EEN pulse will indicate the active accumulation time, and a WEN pulse 
indicates that the resulting video is being read out. 
 
To use this mode:  
Set function: 
Trigger mode “Smearless read out”  
            TR = 6 
 
Shutter mode “Normal” or “Programmable” 
SM=0, SM=1 
 
 
“Shutter Speed” 
SH=0 through 9 
 
“Programmable exposure” 
PE=1 through 1023 
 
Polarity and other functions 
Input: 
Ext. trigger to pin 5 on 6 pin connector (or pin 11 on 12-pin connector). 
 
Ext. HD to pin 6 on12-pin connector. (If used). 
  
Important notes on using this mode.
 
•  The start of exposure will start synchronized to the internal H signal. The start may be 
shifted max 1H. To avoid this shift (1 H jitter), synchronize the camera to an external HD 
and make sure that the trigger pulse aligns to the HD as shown in fig. 17. 
•  The duration of the trigger should be >1H to <2000H. 
•  A new trigger must not be applied before WEN is high. 
•  In trigger modes there are no continuous VD out, only after each trigger input. 
 
No equalize and serration pulses.
 
 
 
Scan mode 
CCD array line #
 
Effective video 
Max frame rate 
fps 
Remarks 
Full  
10H  14H  4 to 1038 
1035H 
18H 
15 
 
1/2 Partial 
17H  33H  271 to 783 
513H 
25H 
26 
 
1/3 Partial 
17H  33H  357 to 697 
341H 
25H 
35 
 
1/6 Partial 
17H  33H  442 to 612 
171H 
25H 
54 
 
H binning 
10H  14H  4 to 1038 
1035H 
18H 
15 
 
V binning 
10H 14H 18 
to 
1019 
501H 
18H 
28 
 
V+H binning  10H 14H 18 
to 
1019 
501H 
18H 
28 
 
 
Fig. 25. Smearless Mode 
 
- 16 - 
JPT  08-10-03:  11:01