Lucent Technologies Release 7 Manual De Usuario
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-517
DIG-LINE (Digital Line)
9
6
ABORT
This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If this
error is present, the release the port via release station
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required for this test are not available.
1392
ABORT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config command
(the display shows a “
(the display shows a “
t
” for the port).
2. If either list config or display port indicate that the port is
not a TTI port,
escalate the problem. If both commands indicate that the port is a TTI port,
the abort is correct, and no action is necessary.
the abort is correct, and no action is necessary.
2000
ABORT
Response to the test was not received in the allowable time period.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
Station Audits passed. This Digital Port circuit pack is functioning properly.
1. If complaints persist, investigate by using other port tests, and by
examining the station, wiring, and connections.
Table 9-211. TEST #17 Station (Digital) Audits Test — Continued
Error
Code
Code
Test
Result
Description/ Recommendation