Error Log Entries and Test to Clear Values
Notes:
a. Craft busied out the Journal Printer Link. The link is torn down. Enter 
release command to restore the link.
b. Link Retry Test (#215) fails. Physical link cannot be set up, usually 
because of hardware problems such as power off or cable disconnect. 
Refer to “Procedures for Restoring the PMS Printer Link” above.
c. Physical link cannot be set up, usually because of hardware problems 
such as power off or cable disconnect. The PMS Printer Link physical link 
is down due to the following causes: cable to the printer device is 
disconnected, the printer device is powered off, or the data extension 
where the printer device connects to has been busied out. Check the 
connectivity of wire and cable among wall jacket, data module, and the 
printer device. Enter status data <extension> and verify that the data 
extension of the printer device is in the in-service/idle state. If the data 
extension is not available, then refer to the ‘‘Procedures for Restoring the 
PMS Printer Link’’ a
bove.
d. Link idle timer; link comes down. This indicates that the printer device is in 
an off-line state, for example, paper jam or paper out. Check the printer 
device and act promptly to put it back to on-line state. Enter test journal 
wakeup-log|pms-log
 command to set up the printer link.
Table 9-507.
PMS-PRNT/JNL-PRNT Link Maintenance Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures. Both PMS Printer and Journal 
Printer are administered to the same extension, and the printer is not connected. Refer to the 
Procedures for Restoring the PMS Printer Link above for resolution.
0
Any
Any
Any
test journal 
wakeup-log|pms-log sh
18 (a)
0
busyout journal 
wakeup-log/pms-log
WARNING
OFF
release journal 
wakeup-log|pms-log
257 (b)
Any
Link Retry Test(#215)
MINOR/
2
 
WARNING
2.
Minor alarms may be downgraded to Warning alarms based on the value used in the set options 
command.
OFF
test journal 
wakeup-log|pms-log l
513 (c)
Any
test journal 
wakeup-log|pms-log
769 (d)