Maintenance Commands 
8-361
test switch-control 
8
test switch-control
test switch-control [C] [short | long] [repeat # | clear] [schedule]
The test switch-control command performs hardware diagnostic tests of the 
PPN Archangel, or SW-CTL circuit, on a specified MSSNET circuit pack. The PPN 
Archangel is responsible for transmitting messages back and forth between the 
SPE and the port circuit packs. For the short test of the active PPN Archangel, a 
loop-around test and a Control Channel test are performed. For the short test of 
the standby PPN Archangel, only the loop-around test is performed.
The long test includes a reset. When applied to the active PPN Archangel, this 
momentarily prevents call origination from stations or trunks connected to ports 
in the PPN. It is non-destructive for existing calls.
Parameters
test synchronization
test synchronization [short | long] [repeat # | clear] [schedule]
The test synchronization command checks the timing synchronization source 
and updates circuit packs with the correct synchronization parameters. The 
tone-clocks, DS1s, and EIs are sent down-link messages to place them in the 
correct synchronization configuration given the current on-line synchronization 
reference.
The synchronization subsystem provides error-free digital communication 
between the switch and other PBXs, COs, or customer premises equipment. The 
subsystem is made up of the TDM bus clock, DS1 trunk circuit packs, and 
maintenance and administration software resident in the SPE.
C
The cabinet is always 1 and need not be entered. Carrier a or b must be 
specified only for systems with duplicated SPEs.
long
This will execute a more comprehensive and longer version of the diagnostic 
tests. When applied to the active PPN Archangel, this momentarily prevents 
call origination from stations or trunks connected to ports in the PPN. It is 
non-destructive for existing calls.