Lucent Technologies Release 7 Manual De Usuario

Descargar
Página de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-138
ASAI-PT 
9
BRI Port Local LAN Looparound Test (#618)
This test is destructive.
This test verifies the connectivity of a BRI port across the LAN Bus and executes 
only if the port is out-of-service. The test aborts if calls associated with the port 
are in-progress. Failures of this test indicate either on-board faults associated 
with the ASAI-PT hardware on the circuit pack or problems with the LAN Bus, 
which is used to form connectivity between the switch and the ASAI-PT.
The dotted lines in 
 show how a Looparound Test is performed across 
the Packet Bus for the D-channel.
Layer 1 Transmission Error Counter Test (#624)
X
ND
Receive FIFO Overflow Error Counter Test (#625)
X
ND
Clear Error Counters (#270)
X
X
ND
1.
D = Destructive, ND = Non-destructive
Table 9-54.
System Technician-Demanded Tests: ASAI-PT — Continued
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Continued on next page