Install and Wire Telephones and Other Equipment
Page 5-8
DS1 Tie Trunk Example
5
DS1 Tie Trunk Example
DS1 tie trunks provide a 1.544 Mbps digital data service between 2 collocated
systems or between the system and a data network using T1 carrier facilities.
DS1 tie trunk circuit packs provide connection capability to the DS1 facility.
systems or between the system and a data network using T1 carrier facilities.
DS1 tie trunk circuit packs provide connection capability to the DS1 facility.
The following cables can be used to connect DS1 tie trunk circuit packs to DS1
digital facilities:
digital facilities:
■
C6C connector cable (comcode 104307327)
—
50-foot (15.24 m)
shielded cable equipped with a 50-pin male connector on 1 end and a
15-pin male connector on the other end. Use this cable to connect a DS1
tie trunk circuit pack to a Channel Service Unit (CSU).
15-pin male connector on the other end. Use this cable to connect a DS1
tie trunk circuit pack to a Channel Service Unit (CSU).
■
C6D connector cable (comcode 104307376)
—
50-foot (15.24 m)
shielded cable equipped with a 50-pin male connector on each end. Use
this cable to connect a DS1 tie trunks in collocated Single-Carrier
Cabinets.
this cable to connect a DS1 tie trunks in collocated Single-Carrier
Cabinets.
■
C6E connector cable (comcode 104307434)
—
100-foot (30.48 m)
shielded cable equipped with a 50-pin male connector on 1 end and a
50-pin female connector on the other end. Use this cable as an
“extension” cable between the DS1 tie trunk circuit pack and other
connector cables.
50-pin female connector on the other end. Use this cable as an
“extension” cable between the DS1 tie trunk circuit pack and other
connector cables.
■
C6F connector cable (comcode 104307475)
—
50-foot (15.24 m)
shielded cable equipped with a 50-pin male connector on 1 end and a
3-inch (7.62 cm) stub on the other end. Use this cable to connect the DS1
tie trunk circuit pack to channel multiplexers requiring hardwired
connections. See
3-inch (7.62 cm) stub on the other end. Use this cable to connect the DS1
tie trunk circuit pack to channel multiplexers requiring hardwired
connections. See
Table 5-1
for a pinout of the C6F cable.
Collocated DS1 Tie Trunks
Connection to 2 TN722B DS1 Tie Trunk circuit packs in collocated systems can
include a C6D cable for distances up to 50 feet (15.24 m). For distances over 50
feet (15.24 m) and up to 1310 Feet (399.3 m) maximum, use C6E cables.
include a C6D cable for distances up to 50 feet (15.24 m). For distances over 50
feet (15.24 m) and up to 1310 Feet (399.3 m) maximum, use C6E cables.
Table 5-1.
Pinout of C6F Cable
Wire Color
Lead Designation
Pin Number
White/Green
L
I
(High Side)
47
Green
L
I
22
White/Brown
LO
48
Brown
LO (High Side)
23
White/Slate
LBACK2
49
Slate
LBACK1
24