13   Configure the alarm settings [Alarm]
The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence, the
VMD area settings, and the alarm occurrence notification can be configured on this page.
The “Alarm” page has 3 tabs; the [Alarm] tab, the [VMD area] tab and the [Notification] tab.
13.1  Configure the settings relating to the alarm
action [Alarm]
Click the [Alarm] tab on the “Alarm” page. (
The settings relating to the alarm can be configured in this section. Refer to page 138 and page 141 for further
information about the settings relating to the alarm images and the alarm output terminal.
Alarm
[Terminal 1]
Determine how to use terminal 1.
Off: Not used.
Alarm input: Receives alarms.
Close 
SW175
SW175
 
SW174W
SW174W
 
SW172
SW172
 
ST165
ST165
 
ST162
ST162
: An alarm is detected when the terminal status
is changed to “On”.
Open 
SW175
SW175
 
SW174W
SW174W
 
SW172
SW172
 
ST165
ST165
 
ST162
ST162
: An alarm is detected when the terminal status
is changed to “Off”.
Black & white input: Receives the black & white switchover input. (When the input is set to On, the black
& white mode is activated.) 
SW396
SW396
 
SW395
SW395
 
SC386
SC386
 
SC385
SC385
Default: Off
[Terminal 2]
Determine how to use terminal 2.
Off: Not used.
Alarm input: Receives alarms.
Close 
SW175
SW175
 
SW174W
SW174W
 
SW172
SW172
 
ST165
ST165
 
ST162
ST162
: An alarm is detected when the terminal status
is changed to “On”.