3com DSA-3CV1001-02 Manual De Usuario

Descargar
Página de 108
Using Front Panel LEDs to Solve Problems
73
VCN AP 
Failure 
Indicated
OFF after 
connection: 
Possible 
causes:
faulty 
power 
adapter
problem 
in the 
VCN AP
Replace ac/dc adapter 
and try again. If the 
problem is eliminated, 
the problem was the 
adapter. If not, the 
problem is in the VCN 
AP; replace it and 
send it to 3Com.
OFF and the 
user data 
cable is 
connected.
ON (green)
One of the items 
below failed:
user data cable
user PC NIC 
VCN AP
Try replacing each of 
the first 2 items. If the 
problem is not 
eliminated, the 
problem is in the VCN 
AP; replace it and 
send it to 3Com.
The Line LED 
does not turn 
steady green 
during 2 
minutes after 
POST
Possible causes are:
no connection
wiring
VCN AC
punch down 
block/patch panel
Power the VCN AP 
OFF, then ON. If the 
VCN AP starts 
properly, the problem 
is solved. If not, 
replace it and send it 
to 3Com.
Table 9   Determining VCN AP status from the LED Indications after POST 
State
Ethernet
Line
Power
Notes