Cisco Systems 6807-XL Manual De Usuario

Descargar
Página de 118
Related Topics
Chassis, on page 2
Environmental Specifications
The following are the environmental specifications of the chassis:
Table 14: Environmental Specifications of the Cisco Catalyst 6807-XL Switch Chassis
Environmental Specification
Item
Certified for operation: 32 to 104 °F (0 to 40 °C).
Designed and tested for operation: 32 to 131 °F (0 to 55 °C).
The Cisco Catalyst 6807-XL switches are equipped with internal
air temperature sensors that are triggered at 104 °F (40 °C)
generating a minor alarm and at 131 °F (55 °C) generating a
major alarm.
Note
Operating temperature
Chassis unpackaged: -4 to 149 °F (-20 to 65 °C).
Chassis in protective shipping package: -40 to 158 °F (-40 to 70 °C).
Nonoperating and storage
temperature
0.5 °C per minute (hot to cold).
0.33 °C per minute (cold to hot).
Thermal transition
5 to 90 percent.
Ambient (noncondensing)
operating humidity (RH)
5 to 95 percent.
Ambient (noncondensing)
nonoperating and storage
humidity
Certified for operation: 0 to 6500 ft (0 to 2000 m).
Designed and tested for operation: -200 to 10,000 ft (-60 to 3000 m) .
Operating altitude
Shock
• Operational—5 G 30 ms, half-sine (IEC 68-2-27).
• Nonoperational—20 G, 7.5 ms, trapezoidal.
Vibration
• Operational—3 to 500 Hz.
• Power Spectral Density (PSD)—0.0005 G2/Hz at 10 and 200 Hz.
5 dB/octave roll off at each end. 0.5 hours per axis (1.12 g).
Shock and vibration
   Cisco Catalyst 6807-XL Switch Hardware Installation Guide
62
OL-30656-01   
Technical Specifications
Environmental Specifications