How Membrane Air Dryer Works
309920D
5
How Membrane Air Dryer Works
Pressure Relief Procedure
The following is a basic pressure relief procedure. Be 
sure to follow the specific pressure relief procedure in 
your spray gun and/or fluid supply equipment manuals.
1.
Close the main air shut-off valve.
2.
Trigger the gun or dispense valve and open any 
drain valves to relieve pressure.
Maintenance
Air Filter with Auto Drain 234402, Series B
To maintain maximum filtering efficiency and avoid 
excessive pressure drop, the filter must be kept clean. 
See Manual 309919 for cleaning and parts information.
Coalescer with Auto Drain 234397, Series B
See Manual 309919 for operation, cleaning, and parts 
information.
Air Regulator 234394
Be sure air to the regulator is clean. Erratic operation or 
loss of regulation is usually caused by dirt in the regula-
tor. See Manual 309924 for cleaning and parts informa-
tion.
Wet air enters 
membrane module
Water vapor purges
Clean, dry air 
exits module
Water vapor permeates through 
hollow membrane fibers
WARNING
To avoid injury, relieve air and fluid pressure before 
checking, cleaning, or repairing the equipment.
Relieve the pressure before cleaning, checking 
or repairing equipment. Follow Pressure 
Relief Procedure
,
 above.
Check system at least once per shift to ensure 
proper drainage.
It is recommended that Air Filter 234402 be 
installed upstream of the coalescing filter to 
remove 3 micron and larger size particles and sep-
arate large droplets of moisture from the air line.
CAUTION
Never let the liquid level in the bowl reach the base of 
the coalescing element.