HP Intelligent Power
HP Intelligent Power
HP Intelligent Power
HP Intelligent Power
Distribution Units
Distribution Units
Distribution Units
Distribution Units (iPDU)
iPDU Core Units
iPDU Core Units
iPDU Core Units
iPDU Core Units
HP 4.9kVA 24A Single Phase NA/JP Core Intelligent Modular Power Distribution Unit
AF520A
HP 8.6kVA 24A Three Phase NA/JP Core Intelligent Modular Power Distribution Unit
AF522A
HP 11.4kVA 16A 415V Three Phase L22-20 NA/JP Core Intelligent Power Distribution
Unit
AF900A
HP 17.3kVA 24A 415V Three Phase L22-30 NA/JP Core Intelligent Power Distribution
Unit
AF902A
HP 17.3kVA 24A 415V Three Phase IEC309 NA/JP Core Intelligent Power
Distribution Unit
AF901A
HP 7.3kVA 32A Single Phase INTL Core Intelligent Modular Power Distribution Unit
AF525A
HP 11kVA 16A Three Phase INTL Core Intelligent Modular Power Distribution Unit
AF526A
NOTE:
NOTE:
NOTE:
NOTE: Please see the QuickSpecs for Technical Specifications and additional
information:
(Worldwide)
 
HP Rack Series
HP Rack Series
HP Rack Series
HP Rack Series
HP Rack 10000 G2 Series
HP Rack 10000 G2 Series
HP Rack 10000 G2 Series
HP Rack 10000 G2 Series (Carbon/Graphite Metallic)
HP 10642 G2 1200mm deep Shock Rack
AF092A
HP 10647 G2 1200mm deep Shock Rack
AF094A
HP 10642 G2 Pallet Universal Rack
AF001A
HP 10642 G2 Shock Universal Rack
AF002A
NOTE:
NOTE:
NOTE:
NOTE: It is mandatory to use a shock pallet when shipping racks with equipment
installed.
NOTE:
NOTE:
NOTE:
NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by
custom systems, VARs and Channels).
NOTE:
NOTE:
NOTE:
NOTE: Please see the QuickSpecs for Technical Specifications and additional
information:
(Worldwide)
NOTE:
NOTE:
NOTE:
NOTE: For additional information regarding Rack Cabinets, please see the following
URL: 
 
NOTE:
NOTE:
NOTE:
NOTE: The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 G2 Series Racks
provide enhanced airflow for maximum cooling, allowing these racks to be fully
loaded with servers using the latest processors.
CAUTION:
CAUTION:
CAUTION:
CAUTION: If a third-party rack is used, observe the following additional requirements
to ensure adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear
doors, you must allow 830 square inches (5,350 sq cm) of hole evenly
distributed from top to bottom to permit adequate airflow (equivalent to the
required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels
of the rack must be a minimum of 2.75 inches (7 cm).
CAUTION:
CAUTION:
CAUTION:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-
 
QuickSpecs
HP ProLiant DL165 Generation 7 (G7)
HP ProLiant DL165 Generation 7 (G7)
HP ProLiant DL165 Generation 7 (G7)
HP ProLiant DL165 Generation 7 (G7)
Additional Options
DA - 13602   Worldwide — Version 23 — November 14, 2011
Page 32