HP 590261-421 Manual De Usuario

Descargar
Página de 48
Power
Power
Power
Power
 
 
ProLiant DL165 G7 Fully Configured
115V/60Hz
220V/50Hz
Fully Loaded System Input Wattage (W)
568
556
Fully Loaded System Input Current (A rms)
4.99
2.58
Fully Loaded System Thermal (BTU- Hr)
1939.15
1898.18
Fully Loaded System VA (Volt-Amp)
574
567
System Inrush Current with all power supplies loaded (A) 30
30
Power cord requirements
Nema 5-15P to IEC320-
C13
IEC320-C13 to IEC320-C14
NOTE:
NOTE:
NOTE:
NOTE: Power shown is for a fully configured system consisting of (2) CPU, (8) double-sided DIMMs, (2) HDDs, (1) CD-ROM, and
(2) PCI cards.
Power Cord
Power Cord
Power Cord
Power Cord
AF556A
 
 
 
 
 
Server Power Cords
Server Power Cords
Server Power Cords
Server Power Cords
One 6' Highline (IEC-IEC) power cord ships standard
NOTE:
NOTE:
NOTE:
NOTE: HP ProLiant DL servers no longer ship standard with NEMA power
cords (163719-002) that allow connection to 110V US wall outlets in a
home or office. ProLiant DL servers are primarily connected to PDU's in
data center racks so they now ship standard with only a PDU power cord
(416151-B21). If a user wishes to power a ProLiant DL server using a
110V receptacle (NEMA-15), the NEMA power cord (227099-001) must
be ordered separately.
If customers require a local power cord, they can check the power cord
matrix for the appropriate cord. Please see the following power cord
matrix: 
.
QuickSpecs
HP ProLiant DL165 Generation 7 (G7)
HP ProLiant DL165 Generation 7 (G7)
HP ProLiant DL165 Generation 7 (G7)
HP ProLiant DL165 Generation 7 (G7)
System Specifications
DA - 13602   Worldwide — Version 23 — November 14, 2011
Page 44