Great Dane GDB10026 Manual De Usuario

Descargar
Página de 88
Troubleshooting - 29
TROUBLESHOOTING
Machine
Park Brake
Battery Will Not Charge
Loose or corroded battery or ground connections.
Blown fusible link (charging circuit).
Battery cables and terminals are dirty.
Dead cell in battery.
PTO Clutch Does Not Engage
Blown 20-amp fuse (main power circuit).
Faulty PTO switch.
Faulty PTO clutch.
Loose PTO clutch connections.
Starter Turns Slowly
Loose or corroded battery or ground connections.
Low battery power - charge battery.
Engine oil viscosity too heavy.
Transaxle linkages failed and are engaged.
If
Check
Excessive Machine Vibration
Engine speed too slow.
Deck drive belts worn or damaged.
Traction drive belt worn or damaged.
Dirt or debris on drive sheaves.
Loose or damaged electric PTO or drive sheave.
Bent or damaged cutting blades.
Machine Will Not Move With Engine Running
Park brake locked.
Transmission hydraulic oil level low.
Transmission oil cold - allow engine to warm.
Traction drive belt slipping.
Transaxle free-wheel valves open.
Traction drive belt damaged or worn.
Transaxle and/or wheel motor problems. See your Great Dane 
servicing dealer.
Machine Creeps With Engine Running and Motion 
Control Levers in a Neutral Position
Needs shift control linkage adjustment.
If
Check
Park Brake Not Working Correctly
Brakes out of adjustment - adjust linkage.
Brake linkage or components damaged.
If
Check