John Deere 5310 S Manual De Usuario

Descargar
Página de 172
Remote Hydraulic Cylinders
GENERIC,000004F
–19–08JUN06–1/1
Connecting Hoses
X9811
–UN–23AUG88
PY5796
–UN–08JUN06
PY5792
–UN–08JUN06
PY5795
–UN–08JUN06
A—Dust Plug
B— Receptacle
CAUTION: Escaping fluid under pressure can
penetrate the skin causing serious injury. Avoid
the hazard by relieving pressure before
disconnecting hydraulic or other lines. Tighten
all connections before applying pressure.
Search for leaks with a piece of cardboard.
Protect hands and body from high pressure
fluids.
If an accident occurs, see a doctor immediately.
Any fluid injected into the skin must be
surgically removed within a few hours or
gangrene may result. Doctors unfamiliar with
this type of injury should reference a
knowledgeable medical source. Such
information is available from Deere & Company
Medical Department in Moline, Illinois, U.S.A.
1. Remove dust caps (if equipped) from hose end.
2. Pull dust plug (A) from couplers.
3. Make sure hose end and coupler receptacles are
clean.
4. Check hoses to see which is used for extending
cylinder. This hose must be connected to a coupler
receptacle (B) in order for cylinder to extend when
SCV levers are moved rearward or inward.
CAUTION: Hydraulic hoses can fail due to
physical damage, kinks, age and exposure.
Check hoses regularly. Replace damaged
hoses. See your John Deere dealer.
5. To connect each hose, push hose tip firmly into
coupler receptacle. Pull lightly on hose to make sure
positive connection was made.
60-2
082206
PN=60