CONTROLS AND FEATURES
See figure 5 for all controls and features 
locations.
Safety Interlock System
Perform the following tests to ensure the 
safety interlock system is working properly. If 
the unit does not perform as stated contact 
your Ariens dealer for repairs.
Ignition Switch
Operate ignition 
switch with a 
removable key. 
Ignition switch has 
four positions: 
Stop (1), Headlight 
(2), Run (3), Start (4). 
See STARTING AND 
SHUTTING OFF 
ENGINE 
on page 16 
for detailed 
instructions on how to 
start engine.
Throttle Lever
Fast (1) – Increases 
engine speed.
Slow (2) – Decreases 
engine speed.
Choke Control
Use to start a cold engine. Push 
the choke lever away from 
operator position to start a cold 
engine. Pull the choke lever 
toward the operator position 
when the engine starts to run 
smoothly. 
NOTE: Do not choke a warm engine.
Parking Brake
Engages (2) and 
disengages (1) parking 
brake.
Power Take-Off (PTO) Switch
Engages (2) 
and disengages 
(1) mower 
blades.
Hour Meter
Press and release the toggle button to shift 
between different functions. 
Press and hold the toggle button to reset the 
timer or clear a service message.
The hour meter has three functions:
Hour Meter: measures the amount of time 
the engine has been run. This time cannot be 
cleared.
OPERATION
WARNING: AVOID INJURY. Read 
and understand the entire Safety 
section before proceeding.
WARNING: Safety interlock failure 
and improper operation of unit can 
result in death or serious injury. 
Check system before each use to 
make sure it is functioning 
properly.
Test Steering 
Lever
PTO
Parking 
Brake
Engine
1
Neutral 
Position
Off
Engaged
Starts
2
Neutral 
Position
On
Engaged
Doesn’t 
Start
3
Neutral 
Position
Off
Disengaged Doesn’t 
Start
4*+
Out of 
Neutral 
Position
Off
Disengaged
Shuts 
Off
5*+
Neutral 
Position
On
Engaged
Shuts 
Off
* Test with engine running.
+ Operator lifts off seat.
1
2
3
4
1
2
1
2
1
2