Dixon ZTR 4516K Manual De Usuario
![Dixon](https://files.manualsbrain.com/attachments/c64546a1da5c1ce28fe28b3b1506b329890cf5b6/common/fit/150/50/785f41662577619992641fdeaabb23bde3e14941839be39077c146cb0361/brand_logo.gif)
Page 37
ELECTRICAL SYSTEM:
Starter will not
turn engine over
turn engine over
Starter will not
turn engine over
turn engine over
Battery discharge
Battery discharge
Battery discharge
TROUBLESHOOTING
Push button to reset
Consult your dealer for repair
Consult your dealer for repair
Charge battery
Tighten or replace as required
Have electrical system checked by your
dealer
dealer
Increase engine RPM
Contact your dealer for information
Contact your dealer for information
REMEDY
Circuit breaker
disengaged
disengaged
Dead Battery
Poor connections on
battery
battery
Battery water low
Wrong battery installed
in mower
in mower
Engine electrical system
not functioning correctly
not functioning correctly
Engine not being
operated at full throttle
operated at full throttle
CAUSES
SITUATION
NOTE:
Electrical system failures are generally simple in nature, always check the obvious first
and then move onto the more complicated parts used.
and then move onto the more complicated parts used.
Poor battery service, loose connections, corrosion, frayed or broken wiring, are more
likely than component failure.
likely than component failure.