Page 10 
2008 Portable Spa Owner’s Manual
 
LTR20081000, Rev. B
Operating Your Spa
Operating Your Spa
5100, 6200 and 6300 
Electronic Control 
Operation
Initial Start up
When first powered up, it will automatically 
revert  to  Priming  mode.    A  Pr  on  the 
topside  display  will  indicate  this.  Priming 
mode  will  be  active  for  less  than  five 
minutes  at  which  time  the  heater  will  be 
activated  and  the  water  temperature  will 
be  maintained  in  Standard  mode.    The 
spa will heat to 100°F (37.5°C) at start up 
until  the  set  temperature  is  changed  as 
described below.
Temperature Adjustment
(Range 80°F to 104°F, 26°C to 40°C)
The  6200  and  6300  electronic  control  panels  display 
the  actual  water  temperature  in  degrees  Fahrenheit.  
The displayed temperature will only be current after the 
pump has been running for at least two minutes.
To display the temperature that the spa is set to:
Press the Temp button. The temperature setting will 
flash.
While the display is flashing, each time you press 
Temp button, the set temperature will change up or 
down one degree.
If the desired temperature is opposite of the direction 
each press of the button is making, release button, 
allow display to stop flashing and then press Temp 
button to change temperature the other direction. 
Standard, Economy and Sleep Heating 
Modes
Your  new  spa  is  equipped  with  a  heating  feature  that 
gives  you  complete  control  of  the  heating  system. 
When the spa is powered up, it will automatically start in 
standard heating mode.
St
 will light briefly on the main display.  In this mode, 
the  heating  system  will  automatically  maintain  the 
set spa temperature. In the economy-heating mode, 
the heating system will only activate during filtration 
times.
Ec  will  display  solid  if  temperature  is  not  current 
and will alternate with spa temperature if measured 
temperature is current.
Economy  mode  will  heat  the  water  to  the  set 
temperature  while  Sleep  mode,  indicated  by  a  SL 
on the main display, will also only activate the heater 
during  the  filtering  cycles  but  will  only  heat  the 
water to within 20°F (10°C) of the set temperature. 
Like  Economy  mode,  SL  will  display  solid  when 
temperature  is  not  current  and  will  alternate  with 
actual temperature when it is current. 
NOTE: Displayed temperature will only be current after 
the pump has been running for at least two minutes.
Switching Modes
Press Temp button followed by the Light button.
Press  the  same  sequence  to  switch  to  the  next 
mode.
Jets
Press the Jets button:
Once to activate low speed pump.
Twice to activate high speed.
Three times to turn pump off.