NOTE:  Circuit  board  programming  will  not  allow  spa  operation  without 
both the temperature and high limit sensors being properly connected to 
the circuit board.
Once topside panel operation is verified. Turn off power, disconnect 
7. 
the extension loom from the circuit board and GENTLY route through 
conduit to complete installation.
NOTE: This loom and its connector are not meant to withstand heavy pull-
ing. Make sure, when routing the extension loom and temperature sensor 
lines through conduit, you exercise extreme caution.
Once properly run through the conduit, repeat steps 5 and 6 above.
In-Ground Spa Light Installation Instructions
On spas ordered with in-ground lights, the factory installs the light niche 
for you. The next steps of installation should be performed by a qualified 
licensed electrician.
Always read and follow light manufacturer’s safety and installation instruc-
tions prior to installation and operation. Incorrect installation may damage 
the light and void its warranty.
The  light  circuit  must  be  on  a  GFCI  protected  service  (alone  or  with  a 
switch).
The water resistant junction box (or for 12 volt models, the low voltage 
transformer) must be located:
at least 8” (20 cm) above water level
• 
at least 4” (10 cm) above ground level, and
• 
at least 48” (121 cm) away from the spa.
• 
See figure below.