J-400 Series
15.4  Ozone water maintenance system (Optional)
This system is optional on North American models and standard 
equipment on export 50 Hz modes. If you spa is equipped with the 
Jacuzzi CD ozone water purification system you will find that your water 
stays fresh and clear with significantly less chemical usage. You will 
probably be able to go longer between complete spa drainings. 
note: To maximize sanitation benefits from this product, always turn off 
the spa waterfall valve when the spa is covered or not in use. This setting 
ensures maximum water flow through the ozone injector and higher 
ozone concentrations. The ozone only runs when the circulation pump is 
running and shuts off when either jets pump is manually activated during 
spa use. The circulation pump will remain off for 5 minutes after both jets 
pumps time out or are manually turned off, then resume operation as 
programmed.
16.0  error/Display messages
There are a number of unique functions designed into your Jacuzzi spa 
to protect it from damage and/or to aid in troubleshooting. When an error 
occurs the spa will notify you by showing the screen below and an error 
code next to it. Following is a listing of all the possible messages along 
with their meanings:
1. 
Overheat protection: (Heater is deactivated, filter/circulation pump is 
activated). Water temperature is above acceptable limits. DO nOT 
enTer THe waTer! Remove spa cover to speed cooling. See 
“Water Is Too Hot” on page 78. If condition persists, contact your 
authorized dealer or authorized service center.
2.  Water is below set-temp: If the spa water is more than 20 °F/6 °C 
cooler than the temperature set point, the circulation pump and 
heater will automatically activate to provide freeze protection. The 
spa will stay in this mode until the water temperature reaches 
15 degrees below the set temperature. No corrective action is 
necessary.
98
F
Temp.
4:05 PM
!
“Displays 
Error 
Message”
warnInG:  rIsK OF HYPerTHermIa (OVer-HeaTInG) 
Causing severe inJury, burns, or welts.
!