TROUBLESHOOTING
SYMPTOM 
 
 
 
PROBABLE CAUSE 
 
 
REMEDY
Water is leaking under heat  
 
Coil drain plug is not installed.   
Install.
exchanger coil.
 
 
 
 
 
 
 
 
 
 
Safety relief device is relieving    
 
1.  Detect  and  correct  unloader  or  
 
 
 
 
 
 
 
 
 
 
caused by an unloader or pressure   
 
pressure  switch  problem. 
 
 
 
 
 
 
 
 
 
 
switch problem.  
 
 
 
 
 
2.  Replace safety relief device.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NEVER  run  unit  without  safety  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
relief device.  Doing so can cause  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
an explosion!   
 
 
 
Burner will not ignite 
 
 
Burner switch is not turned on.   
Check switch position. 
 
 
 
 
 
 
 
 
 
 
 
Out of fuel. 
 
 
 
Refuel. 
 
 
 
 
 
 
 
 
 
 
 
Trigger gun is closed.   
 
Open trigger gun for pressure. 
 
 
 
 
 
 
 
 
 
 
 
EMF Drive belt loose or broken.  
Adjust or replace as necessary. 
 
 
 
 
 
 
Flexible coupler broken.  
 
Replace. 
 
 
 
 
 
 
 
 
 
 
 
Dirty or clogged fuel filter/water sep. 
Drain or replace as necessary. 
 
 
 
 
 
 
Fuel pump sucking air.   
 
Tighten all fuel intake connections. 
 
 
 
 
 
 
 
 
 
 
Eliminate leaks in intake line. 
 
 
 
 
 
 
 
 
 
 
 
Fuel pump inoperative.   
 
Check pressure, replace if needed. 
 
 
 
 
 
 
Fuel pickup screen is obstructed. 
Consult Service. 
 
 
 
 
 
 
Dirty or clogged fuel nozzle. 
 
Replace fuel nozzle. 
 
 
 
 
 
 
Ignition module.  
 
 
Consult Service. 
 
 
 
 
 
 
Ignition electrodes damaged or worn.  With unit running and trigger gun  
 
 
 
 
 
 
 
 
 
 
closed, look through burner sight  
 
 
 
 
 
 
 
 
 
 
glass to ensure there is sparking  
 
 
 
 
 
 
 
 
 
 
across electrodes. 
 
 
 
 
 
 
No voltage. 
 
 
 
Consult Service. 
 
 
 
 
 
 
Pressure switch override. 
 
Pressure should be over 250 PSI/ 
 
 
 
 
 
 
 
 
 
 
18 Bar to allow burner to come on. 
 
 
 
 
 
 
High limit switch override. 
 
Allow unit to cool down before    
 
 
 
 
 
 
 
 
 
 
reigniting. 
 
 
 
 
 
 
Improper burner air adjustment.  
Adjust as shown on page 18. 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fuel solenoid valve failure. 
 
Replace. 
Burner runs erratically.   
 
Water in the fuel oil. 
 
 
Drain fuel filter/water separator,   
 
 
 
 
 
 
 
 
 
 
drain fuel tank and replace with   
 
 
 
 
 
 
 
 
 
 
clean fuel. 
 
 
 
 
 
 
Dirty fuel filter/water separator.   
Replace element. 
 
 
 
 
 
 
Dirty fuel nozzle. 
 
 
Replace. 
 
 
 
 
 
 
Improper air adjustment setting.  
Adjust as shown on page 18. 
 
 
 
 
 
 
Fuel pickup screen is obstructed. 
Consult Service. 
 
 
 
 
 
 
Fuel pump malfunctioning. 
 
Replace. 
Burner runs, but will not heat.   
Poor or improper fuel supply. 
 
Check fuel to ensure it is correct.   
 
 
 
 
 
 
 
 
 
 
Drain tank and filter if necessary  
 
 
 
 
 
 
 
 
 
 
and refill with proper fuel. 
 
 
 
 
 
 
Low fuel pump pressure. 
 
Check fuel pump pressure, replace  
    
 
 
 
 
 
 
 
 
if needed. 
 
 
 
 
 
 
Dirty fuel nozzle. 
 
 
Replace. 
 
 
 
 
 
 
Improper air adjustment setting.  
Adjust as shown on page 18. 
 
 
 
 
 
 
Fuel pickup screen is obstructed. 
Consult Service. 
 
 
 
 
 
 
Scale build up in heat exchanger coil.  Consult Service. 
Burner discharges white smoke.  
Low on fuel. 
 
 
 
Refuel.  If white smoke persists,  
 
 
 
 
 
 
 
 
 
 
consult Service. 
 
 
 
 
 
 
Excessive air supply.   
 
Adjust as shown on page 18. 
Burner discharges black smoke.  
Insufficient air supply.   
 
Adjust as shown on page 18.