PuMP Oil
This pump does not require periodic changing of the oil. It 
uses a high grade synthetic oil which will last for the 
life of the pump. 
P07-0
07
Preparing the Washer
COnneCT hOses and PriMe PuMP
IMPORTANT: Be sure that inlet water screen (C) is clean and in 
place before connecting water supply hose to  
washers.  The water pump and valves could 
be damaged from contaminants.
NOTE: Filling supply hose with water before attaching to pump 
will greatly reduce priming time.
.  Prime water supply hose.  Shut off water.
.  Connect water supply hose to washer inlet (B).  Be sure 
water supply and hose meet specifications.  Do not turn 
water on at this time.
CauTiOn:    Check  pressure  rating  printed  on  the 
hose.  Use proper hoses.  
.  Connect high pressure hose screw connect (D) to washer 
outlet (A). Screw clockwise to tighten.
4.  Open water supply.  Squeeze trigger on gun.  Allow water to 
run (without engine running) until water runs out of pressure 
hose.  Start engine and cycle trigger on gun until “crackling” 
sound (air in lines) stops.  Turn off water supply.
P
07-0
07
a
b
C
P
0-0
07
d