Desa SPC-21PHTSA Manual De Usuario

Descargar
Página de 44
www.desatech.com
114082-01A
6
OPERATING 
INSTRUCTIONS
PREPARING FOR OPERATION
1.  Check heater for possible shipping damage. If 
any is found, immediately notify the factory.
2.  Follow all safety information. 
3.  Make sure control knob is in the OFF position.
4.  Open door to propane/LP cylinder housing by 
turning latching knob counterclockwise.
5.  Check regulator inlet and propane/LP cylinder 
for  contamination  such  as  dirt,  webs,  etc. 
Clean if needed.
6.  Screw threaded end of propane/LP canister 
clockwise into threaded regulator inlet until 
hand tight.
IMPORTANT:
 Use only standard 16.4 oz propane/LP 
cylinder constructed and marked in accordance 
with the U.S. Dept. of Transportation (D.O.T.) 
No. 600 connection type. Disconnect the cylinder 
when the appliance is not in use.
7.  Apply a soap and water solution to connection 
at regulator and cylinder. Bubbles forming 
show a leak.
8.  In case of any leaks, remove propane/LP cyl-
inder. Check and clean connection. Reconnect 
regulator and propane/LP cylinder and leak 
test again. If leak persists, call DESA Heating 
Products at 1-866-672-6040.
9.  Close and latch door
TO START HEATER
1.  Turn gas control knob clockwise to OFF posi-
tion.
2.  Push in and turn gas control knob counter-
clockwise to ON/HIGH. This will light the 
burner. If necessary, keep pressing and turning 
knob clockwise then counterclockwise until 
burner lights.
3.  Keep control knob pressed in for at least 30 
seconds after lighting burner. After 30 seconds 
release control knob.
4.  If the burner does not stay lit, turn control 
knob clockwise to OFF immediately, wait 5 
minutes then repeat steps 2 and 3.
5.  When burner is lit, turn gas control knob to 
desired setting.
TO STOP HEATER
1.  Turn control knob clockwise to OFF position.
2.  If heater is not to be relit, remove propane/LP 
cylinder by rotating counterclockwise. Re-
move cylindr when heater is not in use.
3.  Do not relight heater for 5 minutes after pro-
pane/LP cylinder has been removed.
TO RESTART HEATER
1.  Turn control knob clockwise to OFF position.
2.  Wait 5 minutes.
3.  Restart following To Start Heater.
 
WARNING: FOR YOUR SAFETY
If you smell gas:
•  Shut  off  gas  to  the  appli-
ance.
•  Extinguish any open flames.
•  If odor continues, immediately 
call your gas supplier.
See Safety Information, page 2 
for more information.
PROPANE/LP SUPPLY
Propane/LP gas and propane/LP tank(s) are to be 
furnished by the user. The propane/LP cylinder 
to be used must be constructed and marked in 
accordance with the specifications for the pro-
pane/LP gas cylinders of the U.S. Department of 
Transportation (DOT).
Use  this  heater  only  with  a  propane/LP  vapor 
withdrawal supply system. See Chapter 5 of the 
Standard for Storage and Handling of Liquefied 
Petroleum Gas, ANSI/NFPA 58 and/or CAN/CGA 
B149.2. Your local library or fire department will 
have this booklet.
The amount of propane/LP gas ready for use from 
propane/LP tanks varies. Two factors decide this 
amount: 
1.  The amount of propane/LP gas in tank(s) 
2.  The temperature of tank(s)