Hunter ON/OFF Fan & Light Control
Model 27157
Ratings:  
120 VAC, 60 Hz,1.0 Amp Fan  
Receiver Weight: 6 oz.
 
300 Watts incandescent light
Read and Save these Instructions
Caution: Risk of Electrical Shock!
All wiring must be performed in accordance with national 
and local electrical codes. If you are unfamiliar with the 
wiring codes, you should use a qualified electrician. 
To avoid overheating and possible damage to other 
equipment, do not install to control a receptacle, 
fluorescent light fixture, motor operated appliance, or 
transformer-supplied appliance. Use only to control one 
paddle-blade ceiling fan and incandescent light fixture.
Notes:
1. This device complies with Part 15 of the FCC Rules. Operation is subject 
to the following two conditions: (1) this device may not cause harmful 
interference, and (2) this device must accept any interference received, 
including interference that may cause undesired operation.
2. This equipment has been tested and found to comply with the limits for 
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful interfer-
ence in a residential installation. This equipment generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance 
with the instructions, may cause harmful interference to radio communica-
tions. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference 
to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interfer-
ence by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to 
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
3. For use only with electrically reversible ceiling fans rated at 1.0 amp or 
less, and fan incandescent light kits rated at 300 watts or less.
4. Not for use with shaded-pole motors. Not recommended for use with 
the Hunter Original®. For Hunter Original® series fans, use Hunter control 
model numbers 27187, 22691, or 27189.
5. This product is intended for use with a single switch. If more than one 
switch is being used to control the fixture, consult a qualified electrician 
for assistance.  
Any changes or modifications to this equipment not expressly approved by 
Hunter Fan Company will void the user’s authority to operate the equip-
ment.
Before Installing the Control:
1. Use the pull-chain switch on the fan to set the fan speed to the HIGH 
position before installation. 
2. Set the ceiling fan light kit to the ON position before installation. The 
light setting should only be changed by the Hunter control.
Receiver Installation:
1. Disconnect power to the ceiling fan and light kit at the main electrical 
panel. Remove fuse or move circuit breaker to the OFF position.
2. IMPORTANT! Before installing this control, check the factory default 
jumper settings on the transmitter and the dip switches on the receiver. 
Refer to Figure 1. Be sure the jumper positions of the transmitter and dip 
switch positions on the receiver match, or the ceiling fan will not function. 
Select different combinations of dip switches and jumpers to prevent mis-
operation due to other remote control fans.
3. Determine your ceiling fan mounting type (Figure 2). Most installa-
tions will be one of these four types: Canopy Hanger, Hunter Hands-Free
TM
 
Canopy, Low Profile Styles I and II, or Bracket Hanger.
4. Install the ceiling fan according to its instructions, up to the point of 
making the electrical connections. Connect receiver to ceiling fan accord-
ing to the mounting type as instructed in Figure 2.
5. If the fan is already installed, turn the power OFF at the main electrical 
panel. Reverse the installation procedure according to the fan instructions, 
to the point of disconnecting the fan wiring. Connect the receiver to the 
ceiling fan according to the mounting type as instructed in Figure 2.
6. Use the 2 large wire nuts supplied to connect the receiver and house 
wiring, then use the 3 small wire nuts supplied to connect the receiver and 
ceiling fan wiring. Refer to the Wiring Diagram in Figure 3.
7. Be sure the antenna is positioned securely, so it can not interfere with 
the ceiling fan motor. Refer to Figure 2. Do not modify or damage the 
antenna wire, as control performance may be reduced. After securing the 
receiver, antenna, and wiring, finish hanging the ceiling fan according to 
its instructions.
Fan Installation Types:
NOTE: Some fans may have considerable excess lead wire. For easier 
canopy installation, cut the excess wire leaving a minimum of 6 inches  
remaining. Restrip the fan lead wires 1/2 inch. Place remaining excess wire 
into the ceiling electrical box as needed.
Canopy Hanger (Fig. 2-A): Place receiver in canopy. Connect wiring as 
shown in Figure 3. Extend antenna through one of the ceiling plate open-
ings (approximately 3–6˝).
Hunter Hands-Free™ Canopy (Fig. 2-B): Connect wiring as shown in 
Figure 3. Place receiver inside mounting bracket. Extend antenna above 
the ceiling mounting bracket (approximately 3–6˝).
Low Profile Style I (Fig. 2-C): Secure receiver to the fan plate above the 
motor with UL listed cable ties (not included). Connect wiring as shown 
in Figure 3. Extend antenna through one of the ceiling plate openings 
(approximately 3–6˝).
Low Profile Style II (Fig. 2-D): Secure receiver to the ceiling mounting 
bracket with UL listed cable ties (not included). Connect wiring as shown 
in Figure 3. Extend antenna above the ceiling mounting bracket (approxi-
mately 3–6˝).
Bracket Hanger (Fig. 2-E): Starting with the antenna wire, slide receiver 
inside mounting bracket. If a ground wire mounting screw prevents the 
receiver from sliding into the bracket, move ground wire and screw to an 
unused hole at the top of the bracket or secure with a canopy mount-
ing screw. The bracket must remain properly grounded. Connect wiring 
as shown in Figure 3. Extend antenna above the receiver (approximately 
5–8˝).
Cable Tie Routing for Low Profile Fans (Figs. 2-C, 2-D): Insert cable tie 
through openings as shown. DO NOT insert the cable 
tie through the inside of the receiver. The cable tie 
can be placed across the length or width of the 
receiver to best match your fan installation type.
Fig. 2-A
Fig. 2-B
Figure 2
Ceiling
Plate
Receiver
Canopy
Antenna
Ceiling
Plate
Receiver
Canopy
Antenna
Ceiling
Bracket
Receiver
Receiver
Placement
On Motor
Fan
Motor
Motor
Mounting
Plate
Antenna
Ceiling
Bracket
Receiver
Fan Body
Antenna
Antenna
Receiver
Canopy
Br acket
Canopy
Hands-Free
TM
Canopy
Low Profile I
Low Profile II
Bracket Hanger
Fig. 2-C
Fig. 2-D
Fig. 2-E
 TROUBLESHOOTING
HUNTER FAN COMPANY CONTROL LIMITED WARRANTY
The Hunter Fan Company makes the following limited warranty to the original purchaser of the Control (“Control”): Your Control is warranted to be free 
from defects in material and workmanship for a period of one year from the date of sale. If the Control malfunctions or fails within the warranty period 
due to a defect in material or workmanship we will replace it free of charge. IF THE ORIGINAL PURCHASER CEASES TO OWN THE CONTROL, THIS WAR-
RANTY AND ANY IMPLIED WARRANTY, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
PURPOSE, ARE VOIDED. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING, BUT 
NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IN RESPECT TO ANY CONTROL, IS EXPRESSLY 
LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH CONTROL. This warranty excludes malfunctions or failures which were 
caused by repairs by persons not authorized by us, mishandling, improper installation, modifications, or damage to the Control while in your possession, 
or unreasonable use. This warranty does not apply to batteries or to deterioration or damage to the product caused by the use of faulty batteries. To 
obtain a replacement, return your Control postage prepaid along with proof of purchase to Hunter Fan Company Service Department at 2500 Frisco Av-
enue, Memphis, Tennessee 38114. IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. SOME STATES 
DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL 
DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO 
HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
Symptom
Possible Causes
Solution
1. No functions operate.
2. Operates only at close range.
3. Inconsistent operation. 
Main Power not restored.
Replace fuse. Turn ON circuit breaker. Turn ON wall switch.
Signal blocked from reaching 
receiver.
Extend antenna into ceiling box, or move it for better 
reception. 
Signal partially blocked from 
reaching receiver.
Change dip switch settings to a different code in both
Transmitter and Receiver.
Fan pull chain not set to ON.
Light pull chain not set to ON.
Receiver wiring incorrect.
Transmitter and receiver dip 
switches do not match.
Battery too weak.
Set fan pull chain to the desired speed.
Set light kit to ON. 
Verify wiring connections.
Set transmitter and receiver to same dip switch setting.
Replace with new, 12 Volt alkaline battery. Refer to Figure 1. 
Battery too weak.
Replace with new, 12 Volt alkaline battery. Refer to Figure 1.
RF interference.
Continuing RF interference.
Extend antenna into ceiling box, or move it for better
reception.
Turn OFF wall switch for 5 seconds, then turn back ON.
42715-01 01/17/2007
Printed in China
ON    DIP
1 2 3 4
Receiver Back
Transmitter Back
Jumpers
Dip Switch
1 2 3 4
12 
VOL
T
Figure 1
Light Kit Control
Fan Control
Figure 4
AC
Po wer
In
Light
Kit
Red
White
Fa n
White/Neutra l
Blac k/Hot
Commo n
Antenna
Figure 3
Wiring  Diagr am
1. Light Operation:
• Press and quickly release the ON or OFF button on the remote control to 
turn the light OFF or ON. (Light will come ON at maximum brightness.)
2. Fan Operation:
• Press and quickly release the ON or OFF button on the remote control to 
turn the fan OFF or ON. 
• To change the fan speed, slowly pull the fan pull-chain switch to select 
the desired speed. 
Black/