Duracell 3220 Manual De Usuario

Descargar
Página de 13
8
RaceAmerica Model 3220 Timer SBD
TIMING A RUN - Finish Differential
Before timing a run, it may be desireable to 
enter the racer numbers so they will appear on the 
printout.  To enter a racer number, press the [9] 
CAR#
 button on the keypad to view the existing 
entries; press [9] again to enter new numbers; press 
[#] ENTER to accept the entries.
To time a run, press the [2] RESET button.  
The  timer  immediately  checks  all  track  sensors 
to insure they are operating and aligned properly.  
The  timer  performs  this  function  automatically 
while displaying [rESEt] in the upper display and  
1 to 6 dashes [------] on the lower LED display.  
If a sensor fails the alignment test by triggering 
during this test, the timer will indicate [-FAiL-] 
[-S-1-2] 
with the misaligned sensor(s) blinking.  If 
Lane 1 and Lane 2 sensor/emitter pairs are aligned, 
the LED display will display [rEAdy ] when it is 
ready to time a run.  Once a  sensor is triggered, 
the display will show [LAnE X] (illuminate the 
Win  Light)  in  the  upper  display  and  will  count 
the difference in the lower display until the other 
lane’s sensor is triggered.  At this point the LED 
display displays [LAnE-X] [XXX.XXX] indicat-
ing  the  winning  lane  and  the  differential  in  the 
upper/lower  displays  respectively.    If  a  printer, 
PC  or  Digital  Display  is  connected,  the  output 
will be sent to these devices at the end of the race.  
To resend the data, press the [0] PRINT button.  
Press [#] ENTER to blank the display.  To review 
the result before another race has begun, press [4] 
DELTA.
  To reset for the next run, press the [2] 
RESET
 button.  If [0] PRINT is pressed and the 
port is configured for a display, the console display 
will show[no] [Print].
If  a  Fail  condition  is  detected,  press  [5] 
ALIGN or [#] ENTER to go to alignment mode 
to correct the bad alignment, press [#] ENTER to 
leave alignment mode.
If the Start Sensor/Switch is not connected, 
ET timing must be OFF in the CONFIG menu.
TIMING A RUN  Finish Differential + ET
Before timing a run, it may be desireable to 
enter the racer numbers so they will appear on the 
printout and in the data transmitted to PC capture 
software.  To enter a racer number, press the [9] 
CAR# 
button on the keypad to view the existing 
entries; press [9] again to enter new numbers; press 
[#] ENTER to accept the entries.  Make sure the 
ET option is ON in the CONFIG menu.
To time a run, press the [2] RESET button.  
The  timer  immediately  checks  all  track  sensors 
to insure they are operating and aligned properly.  
The  timer  performs  this  function  automatically 
while displaying [rESEt] in the upper display and  
1 to 6 dashes [------] on the lower display.  If a 
sensor fails the alignment test by triggering during 
this test, the timer will indicate [-FAiL-] [-S-1-2] 
with the misaligned sensor(s) blinking.   If all sen-
sor/emitter pairs are aligned, the LED display will 
display [rEAdy] when it is ready to time a run.  
Once a  sensor is triggered, the display will show 
[LAnE X] (illuminate the Win Light) in the upper 
display and will count the difference in the lower 
display until the other lane’s sensor is triggered.  
Then the timer will switch to display [LAnE-X] 
[XXX.XXX] 
indicating the winning lane and the 
differential  in  the  upper/lower  displays  respec-
tively.  If a printer, PC or Digital Display is con-
nected, the output will be sent to these devices at 
the end of the race.  To resend the data, press the 
[0] PRINT button.  Press [#] ENTER to blank the 
display.  To review the results before another race 
has begun, press [1] ET or  [4] DELTA.  To reset 
for the next run, press the [2] RESET button.
If  a  Fail  condition  is  detected,  press  [5] 
ALIGN or [#] ENTER to go to alignment mode 
to correct the bad alignment, press [#] ENTER to 
leave alignment mode.
ABORT A RUN PRIOR TO FINISH
To stop the timer during a run or if only one 
racer  finishes  (bye-run),  press  the  [#]  ENTER 
button and the timer will show [Abort] [run] in the 
upper/lower displays; press [#] ENTER again to 
clear the displays.  Available data will be sent to 
printers, PCs and ET displays