J2 HARNESS CONNECTOR
SW2
00.00
J2-1
J2-12
MAKE SURE THE TEST 
PROBE CONNECTOR IS 
MAKING CONTACT 
WITH THE CONNECTOR. 
DOUBLE CHECK TO 
MAKE SURE THAT THE 
TIP IS SHARP.
0
83
Figure 6-60. – Check Idle Control Wiring
RESULTS:
Repair or replace wiring as needed. Refer back to the 
flow chart.
TEST 54 - CHECk IdLE CONTROL 
TRANSFORMERS (ICT)
PROCEDURE:
1. Set a voltmeter to measure resistance.
2. Remove  the  two  Idle  Control Transformer  (ICT) Wires  from
Terminal Block 1 (TB1). See Figure 6-61.
3. Connect one meter test lead to one wire and connect the other
meter  test  lead  to  the  other  wire.  Approximately  100  ohms
should  be  measured.  If  resistance  is  not  measured  repair  or
replace the Idle Control Transformers. If resistance was mea-
sured proceed with Step 4.
4. Set a voltmeter to measure AC Voltage.
5. Connect one meter test lead to one wire and connect the other
meter test lead to the other wire.
6. Turn  the  Idle  Control  Switch  (SW2)  to  OFF. The  generator
should be running at about 60 HZ.
7. Apply a light load to the generator, such as a electric drill.
8. When the drill is activated measure the voltage output. The AC
voltage should measure around 1-2 VAC.
RESULTS:
Refer back to flow chart.
TERMINAL 
BLOCK 
(TB1)
100 ohm
86
15B
167
BLK
0
229
83
BLK
TR2
TR1
Figure 6-61. Check Idle Transformer Wiring
TEST 55 - CHECk TR1 & TR2 WIRINg
TB1
J2 HARNESS CONNECTOR
00.00
86
15B
167
BLK
0
229
83
BLK
TR2
TR1
J2-1
J2-12
MAKE SURE THE TEST 
PROBE CONNECTOR IS 
MAKING CONTACT 
WITH THE CONNECTOR. 
DOUBLE CHECK TO 
MAKE SURE THAT THE 
TIP IS SHARP.
Figure 6-62. – Check TR2 Wiring
section 6
Diagnostic tests
Page 64