GE W650 Prospecto

Descargar
Página de 2
MIG II
G650
G60
W650
GENERATOR
Product Selector Guide
16
G30
489
Overspeed
12
Q
Speed Switch
14
Q
Distance Backup
21
Q
Q
Overexcitation
24
Q
Q
Q
Synchronism check
25
Q
Q
Q
Q
Phase/Auxiliary Undervoltage
27P/A
P
P
P
P/A
P/A
Stator Ground (3rt Harmonic)
27TN
Q
Q
Q
Ground Undervoltage (Fundamental)
27GN
Q
Q
Sensitive Directional Power (F/R/LF)
32
Q
Q
Q
Q
Q
Bearing RTD
38
Q
Q
Q
Loss of Excitation Impedance or React. Power
40
Q
Q
Q
Q
Current Unbalance
46
Q
Q
Q
Q
Q
Q
Negative Sequence Overcurrent
50_2/51_2
Q
Q
Q
Q
Voltage phase reversal
47
Q
Q
Q
Q
Q
Inadvertent/Accidental Energization
50/27
Q
Q
Q
IOC, Ground/Neutral/Phase/Negative Sequence
50G/N/P/Q
P/N
G/N/P
G/N/P/Q
G/N/P/Q
G/N/P
G/N/P
IOC, Sensitive Ground
50SG
Q
Q
Q
Q
TOC, Ground/Neutral/Phase/Negative Sequence
51G/N/P/Q
P/N
G/N/P
G/N/P
G/N/P
G/N/P
G/N/P
TOC, Sensitive Ground
51SG
Q
Q
Q
Split Phase
50SP
Q
Q
Voltage Restraint Overcurrent
51V
Q
Q
Q
Q
Q
Breaker Failure
50BF
Q
Q
Q
Logic
Phase/Auxiliary/Neutral Overvoltage
59P/A/N
P/A/N
P/N
P
P/A/N
P/A/N
Ground Overvoltage
59GN
Q
Q
Q
100% Stator Ground
64G
Q
Q
Q
Current Directional, Ground/Neutral/Phase/Neg. Seq.  67P/G/N/Q
P/G/N
G
P/N/Q
P/N/Q
Out of Step Blocking
68
Q
Out of Step Tripping
78
Q
Q
Voltage Transformer Fuse Failure
VTFF
Q
Optional
Q
Q
Q
Under/Overfrequency
81U/O
3U & 3O
3U & 3O
2U & 2O
Q
Q
Anti-Islanding Protection/Rate of Change of Frequency
81R
Q
Q
Q
Lockout Functionality
86
Q
Q
Ground Differential
87N
Q
Q
Q
Q
Differential
87S
Q
Q
Group Differential
87T
Q
Monitoring of Reactive Power
Q
Q
Q
Remote Display
Q
Redundant Power Supply
Optional
Optional
Option
Non-volatile latches
Q
Q
Programmable Elements
Programmable Logic
Q
Q
Q
Q
Q
FlexElements™
Q
Q
Digital Inputs
2
Up to 32
Up to 32
7
80
80
Contact Outputs
5
Up to 16
Up to 16
6
64
64
Virtual Inputs/Outputs
Up to 32
Up to 32
32/64
32/64
Direct Inputs/Outputs
Up to 512
Up to 512
32
32
Trip/Close Coil Supervision
Optional
Optional
Trip
Trip/Close
Trip/Close
User-Programmable LEDs
Q
Q
Q
Q
Q
User-Programmable Push Buttons
Q
Q
Q
Q
User-Programmable Self Test
Q
Q
Selector Switch
Q
Q
Digital Counters
Q
Q
Q
Q
Q
Digital Elements
Q
Q
Q
Q
IRIG-B Input
Q
Q
Q
Q
Q
Analog Inputs/Outputs
Q
Q
Q
RTD Inputs
12
8
8
Power Factor
Q
Q
Q
Q
Q
Current
Q
Q
Q
Q
Q
Q
Voltage
Q
Q
Q
Q
Q
Voltage 3rd Harmonic
Q
Q
Power - Apparent, Real, Reactive
Q
Q
Q
Q
Q
Current, MW, MVA, Mvar Demand
Q
Q
Q
Energy
Q
Q
Q
Q
Q
Frequency
Q
Q
Q
Q
Q
Temperature
Q
Q
Q
User Programmable Fault Reports
Q
Q
Event Recorder - Number of Events
24
479
479
40
1024
1024
Oscillography - Cycles/Sampling Rate
24
128/64
128/64
64/12
93.5/16
93.5/16
Trip Counters
Q
Q
Q
Q
Q
Data Logger
Q
Q
Q
Q
Q
RS232/RS485 Ports 
Q
Q
Q
Q
Q
Q
Ethernet Communications
Q
Q
Q
Q
Q
Fiber Optic Port
Optional
Optional
Q
Q
GE Modem
ModBus Protocol
Q
Q
Q
Q
Q
Q
ModBus User Map
Q
Q
Q
Q
Q
Q
DNP3 Protocol
Q
Q
Q
Q
Q
EGD Protocol
Q
Q
Peer-to-peer communication (Goose)
Q
Q
Q
Q
IEC 60870-104
Q
Q
Q
Q
IEC 61850 Protocol
Q
Q
Q
Q
Simple Network Time Protocol
Q
Q
Q
PR
O
TECTION
C
ONTR
OL
MONIT
ORING & ME
TERING
FEATURES
DEVICE
MIG
W650
G650
489
G30
G60
C
OMMUNICA
TIONS
* For the most current comparison list, access us online at: 
www.GEMultilin.com/selector/generator.pdf